Development of an IEC 61850 Standard-Based Busbar Protection Scheme

Communication systems of intelligent electronic devices play a huge role in the performance of busbar protection schemes. They determine the effectiveness of the protection scheme in terms of detecting and isolating busbar faults. A literature survey has revealed that multiple proposed algorithms of busbar protection schemes have encountered a common problem of achieving interoperability between intelligent electronic devices produced by different vendors. This affects the performance of busbar protection schemes. This paper focuses on achieving interoperability between IEC 61850 standard-based multi-vendor intelligent electronic devices “SEL and ABB”. This improves the performance of busbar protection schemes between multi-vendor devices, and at the same time increases the operational reliability. The investigation is conducted using a current differential busbar protection algorithm. The study is performed by implementing hardware-in-the-loop (HIL) testing using a real-time digital simulator (RTDS). A laboratory-scale test bench is developed to achieve interoperability between the IEDs SEL-487B and REF615. A fault condition is simulated, and the behaviour of the protection scheme is analysed. The hardware-in-the-loop results demonstrate the benefit of the proposed technique.

Authors

Publication Details

Journal
International Journal of Electrical Engineering and Applied Sciences (IJEEAS)
Published
2024-10-28
DOI
https://doi.org/10.54554/ijeeas.2024.7.01.001
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an IEC 61850 Standard-Based Busbar Protection Scheme

Mkhululi Mnguni, Luntu Siphelo Mgaga
International Journal of Electrical Engineering and Applied Sciences (IJEEAS)
Smart Grid Security and Resilience
article

Development of an IEC 61850 Standard-Based Busbar Protection Scheme

Mkhululi Mnguni, Luntu Siphelo Mgaga
article en

Abstract

Communication systems of intelligent electronic devices play a huge role in the performance of busbar protection schemes. They determine the effectiveness of the protection scheme in terms of detecting and isolating busbar faults. A literature survey has revealed that multiple proposed algorithms of busbar protection schemes have encountered a common problem of achieving interoperability between intelligent electronic devices produced by different vendors. This affects the performance of busbar protection schemes. This paper focuses on achieving interoperability between IEC 61850 standard-based multi-vendor intelligent electronic devices “SEL and ABB”. This improves the performance of busbar protection schemes between multi-vendor devices, and at the same time increases the operational reliability. The investigation is conducted using a current differential busbar protection algorithm. The study is performed by implementing hardware-in-the-loop (HIL) testing using a real-time digital simulator (RTDS). A laboratory-scale test bench is developed to achieve interoperability between the IEDs SEL-487B and REF615. A fault condition is simulated, and the behaviour of the protection scheme is analysed. The hardware-in-the-loop results demonstrate the benefit of the proposed technique.

International Journal of Electrical Engineering and Applied Sciences (IJEEAS)Vol. 7(1)
Openalex Percentile: Top 68%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.