Results of Internal Quality Assurance for Ureum Parameters at H. Andi Sulthan Daeng Radja Hospital

Internal Quality Assurance (PMI) is a preventive and supervisory activity in the laboratory to ensure precise and accurate examination results. This study aims to evaluate the precision, accuracy, and types of analytical errors in PMI urea parameters in the laboratory of H. Andi Sulthan Daeng Radja Hospital, Bulukumba Regency. This descriptive study uses a mixed method with secondary data from PMI results for October–December 2023. The results showed that the average (Mean) urea value in October was 35.53 mg/dL, SD 1.77 mg/dL, CV 4.99%, and d 0.77%; November 35.48 mg/dL, SD 1.74 mg/dL, CV 4.89%, and d 0.88%; December 35.43 mg/dL, SD 1.81 mg/dL, CV 5.10%, and d 1.03%. The CV (precision) and d (accuracy) values are within the maximum control limits (CV ?8%, Bias ±10%). Westgard rule analysis showed violations of the 1-2s rule in October, in the form of warnings without affecting the validity of the control, while no violations were found in November–December. Conclusion: The precision and accuracy of urea parameters are in the good category based on the Levey-Jennings graph analysis and the Westgard rule.

Authors

Publication Details

Journal
Journal of Multidiscipline and Collaboration Research.
Published
2024-12-18
DOI
https://doi.org/10.58740/jmcr.v1i2.284
Primary Topic
Disaster Response and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Results of Internal Quality Assurance for Ureum Parameters at H. Andi Sulthan Daeng Radja Hospital

Asriani Hasanuddin, Asdinar Asdinar, Jusriani Jusriani
Journal of Multidiscipline and Collaboration Research.
Disaster Response and Management
article

Results of Internal Quality Assurance for Ureum Parameters at H. Andi Sulthan Daeng Radja Hospital

Asriani Hasanuddin, Asdinar Asdinar, Jusriani Jusriani
article en

Abstract

Internal Quality Assurance (PMI) is a preventive and supervisory activity in the laboratory to ensure precise and accurate examination results. This study aims to evaluate the precision, accuracy, and types of analytical errors in PMI urea parameters in the laboratory of H. Andi Sulthan Daeng Radja Hospital, Bulukumba Regency. This descriptive study uses a mixed method with secondary data from PMI results for October–December 2023. The results showed that the average (Mean) urea value in October was 35.53 mg/dL, SD 1.77 mg/dL, CV 4.99%, and d 0.77%; November 35.48 mg/dL, SD 1.74 mg/dL, CV 4.89%, and d 0.88%; December 35.43 mg/dL, SD 1.81 mg/dL, CV 5.10%, and d 1.03%. The CV (precision) and d (accuracy) values are within the maximum control limits (CV ?8%, Bias ±10%). Westgard rule analysis showed violations of the 1-2s rule in October, in the form of warnings without affecting the validity of the control, while no violations were found in November–December. Conclusion: The precision and accuracy of urea parameters are in the good category based on the Levey-Jennings graph analysis and the Westgard rule.

Journal of Multidiscipline and Collaboration Research.Vol. 1(2)
Openalex Percentile: Top 55%
Disaster Response and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.