Projection selection and rapid atrial pacing improves early outcomes after self-expanding transcatheter aortic valves

ABSTRACT Introduction and objectives: Because of the potential need for permanent pacemaker implantation, patients are frequently monitored for days after transcatheter aortic valve implantation (TAVI), particularly when using self-expanding valves. We sought to determine whether the appearance and management of conduction disturbances after TAVI can be improved by combining the cusp overlap projection (COP) and a rapid atrial pacing (RAP) protocol to detect the need for pacemaker implantation. Methods: We consecutively studied a total of 273 patients who underwent TAVI with self-expanding valves from 2018 through 2022 (134 undergoing standard implantations and 139 COP + RAP). Assessment included the 90-day follow-up. Results: Complete heart block was reported in 25.4% and 14.4% in the standard-of-care and COP + RAP group, with a marked decrease in transient atrioventricular block (12.8% vs 2.9%, respectively; P = .007). The absence of the Wenckebach phenomenon during RAP had a negative predictive value of 97% (95%CI, 91-99) for pacemaker implantation at the follow-up, which significantly decreased the need for 24-hour temporary pacemaker monitoring in the COP + RAP group (91.8% vs 28.1%; P < .0001) and the median [IQR] length of stay (5.0 [4-8] days vs 2.0 [1-4] days; P < .0001). At the 90-day follow-up, COP + RAP reduced pacemaker implantation (OR, 0.48; 95%CI, 0.24-0.92; P = .031), as well as the risk of infection-related readmissions significantly (OR, 0.35; 95%CI, 0.12-0.89; P = .036). Conclusions: The combination of COP + RAP during self-expanding TAVI improves postoperative screening for conduction disturbances, thus reducing the need for cardiac rhythm monitoring, and the length stay. The COP + RAP strategy improves the short-term clinical outcomes of self-expanding TAVI due to fewer infection-related readmissions.

Authors

Publication Details

Journal
REC interventional cardiology (English Edition)
Published
2025-02-03
DOI
https://doi.org/10.24875/recice.m24000495
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Projection selection and rapid atrial pacing improves early outcomes after self-expanding transcatheter aortic valves

María Tamargo, Mike Huanca, Enrique Gutiérrez‐González, Javier Soriano et al.
REC interventional cardiology (English Edition)
Cardiac Valve Diseases and Treatments
article

Projection selection and rapid atrial pacing improves early outcomes after self-expanding transcatheter aortic valves

María Tamargo, Mike Huanca, Enrique Gutiérrez‐González, Javier Soriano, Jaime Elı́zaga, and Francisco Fernández-Avilés, María Eugenia Vázquez Álvarez, Jorge García-Carreño, Ricardo Sanz‐Ruiz, Javier Bermejo, Erika Ludeña
article en

Abstract

ABSTRACT Introduction and objectives: Because of the potential need for permanent pacemaker implantation, patients are frequently monitored for days after transcatheter aortic valve implantation (TAVI), particularly when using self-expanding valves. We sought to determine whether the appearance and management of conduction disturbances after TAVI can be improved by combining the cusp overlap projection (COP) and a rapid atrial pacing (RAP) protocol to detect the need for pacemaker implantation. Methods: We consecutively studied a total of 273 patients who underwent TAVI with self-expanding valves from 2018 through 2022 (134 undergoing standard implantations and 139 COP + RAP). Assessment included the 90-day follow-up. Results: Complete heart block was reported in 25.4% and 14.4% in the standard-of-care and COP + RAP group, with a marked decrease in transient atrioventricular block (12.8% vs 2.9%, respectively; P = .007). The absence of the Wenckebach phenomenon during RAP had a negative predictive value of 97% (95%CI, 91-99) for pacemaker implantation at the follow-up, which significantly decreased the need for 24-hour temporary pacemaker monitoring in the COP + RAP group (91.8% vs 28.1%; P < .0001) and the median [IQR] length of stay (5.0 [4-8] days vs 2.0 [1-4] days; P < .0001). At the 90-day follow-up, COP + RAP reduced pacemaker implantation (OR, 0.48; 95%CI, 0.24-0.92; P = .031), as well as the risk of infection-related readmissions significantly (OR, 0.35; 95%CI, 0.12-0.89; P = .036). Conclusions: The combination of COP + RAP during self-expanding TAVI improves postoperative screening for conduction disturbances, thus reducing the need for cardiac rhythm monitoring, and the length stay. The COP + RAP strategy improves the short-term clinical outcomes of self-expanding TAVI due to fewer infection-related readmissions.

REC interventional cardiology (English Edition)
Zero hunger
Openalex Percentile: Top 96%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.