Enhancing U-Net-based Pseudo-CT generation from MRI using CT-guided bone segmentation for radiation treatment planning in head & neck cancer patients
<i>Objective.</i>This study investigates the effects of various training protocols on enhancing the precision of MRI-only Pseudo-CT generation for radiation treatment planning and adaptation in head & neck cancer patients. It specifically tackles the challenge of differentiating bone from air, a limitation that frequently results in substantial deviations in the representation of bony structures on Pseudo-CT images.<i>Approach.</i>The study included 25 patients, utilizing pre-treatment MRI-CT image pairs. Five cases were randomly selected for testing, with the remaining 20 used for model training and validation. A 3D U-Net deep learning model was employed, trained on patches of size 64<sup>3</sup>with an overlap of 32<sup>3</sup>. MRI scans were acquired using the Dixon gradient echo (GRE) technique, and various contrasts were explored to improve Pseudo-CT accuracy, including in-phase, water-only, and combined water-only and fat-only images. Additionally, bone extraction from the fat-only image was integrated as an additional channel to better capture bone structures on Pseudo-CTs. The evaluation involved both image quality and dosimetric metrics.<i>Main results.</i>The generated Pseudo-CTs were compared with their corresponding registered target CTs. The mean absolute error (MAE) and peak signal-to-noise ratio (PSNR) for the base model using combined water-only and fat-only images were 19.20 ± 5.30 HU and 57.24 ± 1.44 dB, respectively. Following the integration of an additional channel using a CT-guided bone segmentation, the model's performance improved, achieving MAE and PSNR of 18.32 ± 5.51 HU and 57.82 ± 1.31 dB, respectively. The measured results are statistically significant, with a<i>p</i>-value<0.05. The dosimetric assessment confirmed that radiation treatment planning on Pseudo-CT achieved accuracy comparable to conventional CT.<i>Significance.</i>This study demonstrates improved accuracy in bone representation on Pseudo-CTs achieved through a combination of water-only, fat-only and extracted bone images; thus, enhancing feasibility of MRI-based simulation for radiation treatment planning.
Authors
- Katharina Maria Paul
- Thomas Welzel (ORCID: https://orcid.org/0000-0001-9960-3052)
- Katharina Seidensaal (ORCID: https://orcid.org/0000-0001-5969-6426)
- Sebastian Klüter (ORCID: https://orcid.org/0000-0003-3139-3444)
- Julia Bauer (ORCID: https://orcid.org/0000-0002-7944-3757)
- Kristina Giske (ORCID: https://orcid.org/0000-0001-7287-3271)
- Stefan Dorsch (ORCID: https://orcid.org/0000-0002-8185-8644)
- Ama Katseena Yawson (ORCID: https://orcid.org/0000-0002-6005-7354)
- Habiba Sallem (ORCID: https://orcid.org/0009-0004-7811-7839)
- Cedric Beyer (ORCID: https://orcid.org/0009-0008-5236-2093)
- O. Jaekel (ORCID: https://orcid.org/0000-0002-6056-9747)
- Jürgen Debus
Institutions
- German Cancer Research Center (DE)
- Heidelberg University (DE)
- University Hospital Heidelberg (DE)
- Heidelberger Institut für Radioonkologie (DE)
- National Center for Tumor Diseases (DE)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2025-02-03
- DOI
- https://doi.org/10.1088/1361-6560/adb124
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00