Comparative evaluation of fluoride release profiles in new glass ionomer cements and conventional type II GIC: Implications for cariostatic efficacy

The fluoride release characteristics of two new Glass Ionomer Cements (GICs), Equia Forte HT and Micron Bioactive, with a conventional Type II restorative GIC is of interest. Fluoride release, a crucial cariostatic property, was evaluated using 18 disc specimens prepared in disposable silicone molds and stored in deionized water for 15 days. Measurements taken on days 1, 3, 7 and 14 with a fluoride ion-specific electrode showed that Equia Forte HT exhibited the highest fluoride release, followed by Micron Bioactive and Type II GIC. Statistical analysis, including ANOVA, confirmed significant differences among the groups, highlighting the superior performance of Equia Forte HT. These findings emphasize the importance of selecting GICs with optimal fluoride release for effective dental restorations and call for further research into their long-term clinical performance.

Authors

Institutions

Publication Details

Journal
Bioinformation
Published
2024-12-31
DOI
https://doi.org/10.6026/9732063002002009
Citations
3
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of fluoride release profiles in new glass ionomer cements and conventional type II GIC: Implications for cariostatic efficacy

Sharmila Tapashetti, Priya Horatti, Mehul A Shah, Balaram Naik et al.
3 citations
Bioinformation
Dental materials and restorations
1.21
article

Comparative evaluation of fluoride release profiles in new glass ionomer cements and conventional type II GIC: Implications for cariostatic efficacy

Sharmila Tapashetti, Priya Horatti, Mehul A Shah, Balaram Naik, Migit Michael Dcruz, Prashant Mogi
article en
3 citations

Abstract

The fluoride release characteristics of two new Glass Ionomer Cements (GICs), Equia Forte HT and Micron Bioactive, with a conventional Type II restorative GIC is of interest. Fluoride release, a crucial cariostatic property, was evaluated using 18 disc specimens prepared in disposable silicone molds and stored in deionized water for 15 days. Measurements taken on days 1, 3, 7 and 14 with a fluoride ion-specific electrode showed that Equia Forte HT exhibited the highest fluoride release, followed by Micron Bioactive and Type II GIC. Statistical analysis, including ANOVA, confirmed significant differences among the groups, highlighting the superior performance of Equia Forte HT. These findings emphasize the importance of selecting GICs with optimal fluoride release for effective dental restorations and call for further research into their long-term clinical performance.

BioinformationVol. 20(12)
Sri Dharmasthala Manjunatheshwara College of Dental Sciences & Hospital (IN), Bharati Vidyapeeth (Deemed to be University) (IN)
Clean water and sanitation
Openalex Percentile: Top 23%
Dental materials and restorations
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative evaluation of fluoride release profiles in new glass ionomer cements and conventional type II GIC: Implications for cariostatic efficacy — Sharmila Tapashetti, Priya Horatti, et al. · Bioinformation (2024) | TGRS Research Map | TGRS