Design and test of a robustness evaluation system for micro-vision tracking algorithms

Industrial applications of micro-vision tracking algorithms become increasingly prevalent. Unfortunately, out-of-focused-plane (OFP) disturbances negatively impact the in-focused-plane (IFP) tracking accuracy of the micro-vision. This paper proposes a robustness evaluation system for micro-vision tracking algorithms. The relationship between IFP accuracy degradation/improvement and OFP disturbances is quantified. First, a commercial spatial nanopositioning stage (com-SNPS) and an SNPS designed in the laboratory (lab-SNPS) were employed to build a robustness evaluation system. Two SNPSs were utilized to generate both IFP trajectories and specific OFP disturbances. Capacitive sensors were used to evaluate the IFP accuracy of micro-vision tracking algorithms. Second, traditional micro-vision tracking algorithms were selected. The combination of the constant-template matching method, constant-region-of-interest (constant-ROI) retrieval method, and constant-focused-plane focusing method acted as test examples. Third, robust micro-vision tracking algorithms were developed. The variable-template matching method, variable-ROI retrieval method, and variable-focused-plane focusing method were combined. Finally, the prototype of the proposed robustness evaluation system was tested. The focused plane was determined to be a benchmark for calculating OFP disturbances. The IFP accuracy of chosen algorithms under specific OFP excitation was measured. Test results demonstrate different IFP degradation or improvement characteristics of micro-vision algorithms. This paper contributes to developing a robust micro-vision tracking algorithm.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-02-01
DOI
https://doi.org/10.1063/5.0235785
Citations
3
Primary Topic
Image Processing Techniques and Applications
Type
article
Field-Weighted Citation Impact
3.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and test of a robustness evaluation system for micro-vision tracking algorithms

Ruizhou Wang, Yulong Zhang, Hua Wang
3 citations
Review of Scientific Instruments
Image Processing Techniques and Applications
3.41
article

Design and test of a robustness evaluation system for micro-vision tracking algorithms

Ruizhou Wang, Yulong Zhang, Hua Wang
article en
3 citations

Abstract

Industrial applications of micro-vision tracking algorithms become increasingly prevalent. Unfortunately, out-of-focused-plane (OFP) disturbances negatively impact the in-focused-plane (IFP) tracking accuracy of the micro-vision. This paper proposes a robustness evaluation system for micro-vision tracking algorithms. The relationship between IFP accuracy degradation/improvement and OFP disturbances is quantified. First, a commercial spatial nanopositioning stage (com-SNPS) and an SNPS designed in the laboratory (lab-SNPS) were employed to build a robustness evaluation system. Two SNPSs were utilized to generate both IFP trajectories and specific OFP disturbances. Capacitive sensors were used to evaluate the IFP accuracy of micro-vision tracking algorithms. Second, traditional micro-vision tracking algorithms were selected. The combination of the constant-template matching method, constant-region-of-interest (constant-ROI) retrieval method, and constant-focused-plane focusing method acted as test examples. Third, robust micro-vision tracking algorithms were developed. The variable-template matching method, variable-ROI retrieval method, and variable-focused-plane focusing method were combined. Finally, the prototype of the proposed robustness evaluation system was tested. The focused plane was determined to be a benchmark for calculating OFP disturbances. The IFP accuracy of chosen algorithms under specific OFP excitation was measured. Test results demonstrate different IFP degradation or improvement characteristics of micro-vision algorithms. This paper contributes to developing a robust micro-vision tracking algorithm.

Review of Scientific InstrumentsVol. 96(2)
Guangdong University of Technology (CN)
National Natural Science Foundation of China
Industry, innovation and infrastructure
Openalex Percentile: Top 8%
Image Processing Techniques and Applications
3.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and test of a robustness evaluation system for micro-vision tracking algorithms — Ruizhou Wang, Yulong Zhang, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS