“Don’t stop me now!”: Stopping rules for iterative reconstruction with dimensional X-ray Computed Tomography
X-ray Computed Tomography is regularly exploited in manufacturing, primarily for high-value low-volume cases due to prolonged data acquisition times. For optimal results the Nyquist criterion suggests obtaining 3142 projections for a 2000 pixel width detector reasoning the extended inspection time. Reducing projections enhances speed but the standard FDK reconstruction method suffers a loss in image quality and dimensional accuracy. Iterative reconstruction methods excel with limited data such as fewer projections, offering a promising route forward. However, their application in dimensional measurement has no best practice — particularly when to stop iterating. In this study, a multi-sphere workpiece imaged at 100 μ m was reconstructed using SIRT, an iterative reconstruction algorithm, with just 17% (504 projections) of the projection data. The bi-directional measurements of sphere diameters were compared to the FDK reconstruction of the full dataset. In iterative reconstruction, the images improve with each iteration until a point of semi-convergence where it best represents the object, after which unwanted noise from the projections begins to be added. Without a ground truth image the semi-convergence is inferred by semi-convergence of measurement. Here, the difference in the sphere diameter against the FDK measurement is at most 0.0295 voxels ( 2 . 95 μ m ) which is the same magnitude of error as repeated acquisitions with FDK reconstruction of a full dataset. Image metrics are evaluated as a less expensive way to identify the semi-convergence of measurement. In particular anisotropic quality index (AQI) and sharpness are identified candidate rules, as well as highlighting a number of other reasonable stopping rules which were unsuccessful in this scenario. While they cannot identify the precise diameter minima, they are all within 0.008 voxels (0.8 μ m) of the semi-convergence point. Iterative reconstruction is a promising route forward to decrease inspection times with comparably accurate and repeatable measurements if the decision of when to stop iterating is well justified. • Iterative reconstruction can exploit limited data for CT dimensional measurement. • Stopping rules must be used for accuracy and repeatability. • Anisotropic quality index and sharpness are candidate stopping rules for measurement. • Comparable measurements in sphere diameters were achieved with 17% of typical data.
Authors
- Jason M. Warnett (ORCID: https://orcid.org/0000-0003-2284-790X)
- E.A. Zwanenburg (ORCID: https://orcid.org/0000-0002-4776-5567)
- Mark A. Williams (ORCID: https://orcid.org/0000-0003-3802-7914)
- S. Harris (ORCID: https://orcid.org/0000-0003-1531-4822)
Institutions
- University of Warwick (GB)
Publication Details
- Journal
- Precision Engineering
- Published
- 2025-02-03
- DOI
- https://doi.org/10.1016/j.precisioneng.2025.01.019
- Citations
- 1
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.36
Funders
- University of Southampton
- Engineering and Physical Sciences Research Council