Experimental optimization of an absorption-compression heat pump with wet compression for large temperature glide industrial applications

The present work demonstrates the experimental optimization of a single-stage compression-absorption heat pump system for an application with a large temperature glide on the heat sink side using wet compression. The primary focus is weak solution injection to optimize the compressor discharge temperature and absorber heat sink temperature glide optimizations and their effect. With constant heat sink and source inlet temperatures at 60 °C and a mass flow rate of 0.25 kg/s, preliminary results show that the system delivers 50 kW of heating load and 26 kW of cooling load, respectively. Increasing the heat sink temperature glide between 28 °C and 48 °C reduces Lorenz COP and improves system efficiency. A weak solution mass flow rate of 0.015–0.25 kg/s with a minimum absorber pressure of 15 bar is recommended to achieve a higher heat sink temperature glide. Increasing the weak solution injection flow rate from 0 to 0.03 kg/s decreases the compressor discharge temperature from 139 °C to 122 °C, with a constant 0.0015 kg/s injection directed to the bearing and shaft seal. The results also highlight differences in the overall heat transfer coefficients and heat flux between absorbers 1 and 2. Absorber 1, operating in bubble mode, performs better with a maximum heat transfer coefficient of 1.39 kW/m 2 K compared to absorber 2, which operates in falling film mode. The system’s performance and behavior are comprehensively evaluated, providing a foundation for future improvements and advancements in oil-free absorption-compression heat pump technology.

Authors

Institutions

Publication Details

Journal
Renewable Energy
Published
2025-02-03
DOI
https://doi.org/10.1016/j.renene.2025.122531
Citations
9
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
6.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental optimization of an absorption-compression heat pump with wet compression for large temperature glide industrial applications

Ignat Tolstorebrov, Armin Hafner, Ole Marius Moen, Uzair Sajjad et al.
9 citations
Renewable Energy
Refrigeration and Air Conditioning Technologies
6.42
article

Experimental optimization of an absorption-compression heat pump with wet compression for large temperature glide industrial applications

Ignat Tolstorebrov, Armin Hafner, Ole Marius Moen, Uzair Sajjad, Trygve Magne Eikevik, Cordin Arpagaus, Shuai Ren, Khalid Hamid
article en
9 citations

Abstract

The present work demonstrates the experimental optimization of a single-stage compression-absorption heat pump system for an application with a large temperature glide on the heat sink side using wet compression. The primary focus is weak solution injection to optimize the compressor discharge temperature and absorber heat sink temperature glide optimizations and their effect. With constant heat sink and source inlet temperatures at 60 °C and a mass flow rate of 0.25 kg/s, preliminary results show that the system delivers 50 kW of heating load and 26 kW of cooling load, respectively. Increasing the heat sink temperature glide between 28 °C and 48 °C reduces Lorenz COP and improves system efficiency. A weak solution mass flow rate of 0.015–0.25 kg/s with a minimum absorber pressure of 15 bar is recommended to achieve a higher heat sink temperature glide. Increasing the weak solution injection flow rate from 0 to 0.03 kg/s decreases the compressor discharge temperature from 139 °C to 122 °C, with a constant 0.0015 kg/s injection directed to the bearing and shaft seal. The results also highlight differences in the overall heat transfer coefficients and heat flux between absorbers 1 and 2. Absorber 1, operating in bubble mode, performs better with a maximum heat transfer coefficient of 1.39 kW/m 2 K compared to absorber 2, which operates in falling film mode. The system’s performance and behavior are comprehensively evaluated, providing a foundation for future improvements and advancements in oil-free absorption-compression heat pump technology.

Renewable EnergyVol. 243
King Fahd University of Petroleum and Minerals (SA), SINTEF (NO), Norwegian University of Science and Technology (NO), OST - Ostschweizer Fachhochschule (CH)
Affordable and clean energy
Openalex Percentile: Top 3%
Refrigeration and Air Conditioning Technologies
6.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.