Saliva Glucose Determination by Biosensor: Method Comparison to Chemiluminescence Immunoassay

The noninvasive sampling materials and methods have garnered great interest among researchers. Saliva is considered the most popular material, and glucose is one of the most commonly used biochemical parameters. This article provides a comparison between the biosensor and autoanalyzer methods for saliva glucose measurement and identifies its potential as a point-of-care testing tool. The experiments were performed using salivary samples from twenty-six adults collected using saliva collection tubes. The swabs were soaked in saliva for 1 min and then centrifuged for 10 min at 1500 g. Glucose concentrations were determined using two methods: one based on an autoanalyzer using chemiluminescence assay and the other based on a biosensor using glucose oxidase enzyme-based amperometric method. A statistically significant correlation was found between the two methods (r = 0.802; p < 0.001). The most remarkable result from the data is that there were no significant differences in saliva glucose measurements between the two methods. This paper presents an innovative biosensor method that can be readily used in practice for rapid results, low cost, and specificity compared to the frequently used autoanalyzer method.

Authors

Institutions

Publication Details

Journal
Biochemistry (Moscow) Supplement Series B Biomedical Chemistry
Published
2024-12-01
DOI
https://doi.org/10.1134/s1990750824600286
Citations
1
Primary Topic
Salivary Gland Disorders and Functions
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Saliva Glucose Determination by Biosensor: Method Comparison to Chemiluminescence Immunoassay

Umut Kökbaş, Rabia Şemsi, Burak Arslan, Erdal Ergünol et al.
1 citations
Biochemistry (Moscow) Supplement Series B Biomedical Chemistry
Salivary Gland Disorders and Functions
0.33
article

Saliva Glucose Determination by Biosensor: Method Comparison to Chemiluminescence Immunoassay

Umut Kökbaş, Rabia Şemsi, Burak Arslan, Erdal Ergünol, Aylin Sepici Dinçel, Levent Kayrın
article en
1 citations

Abstract

The noninvasive sampling materials and methods have garnered great interest among researchers. Saliva is considered the most popular material, and glucose is one of the most commonly used biochemical parameters. This article provides a comparison between the biosensor and autoanalyzer methods for saliva glucose measurement and identifies its potential as a point-of-care testing tool. The experiments were performed using salivary samples from twenty-six adults collected using saliva collection tubes. The swabs were soaked in saliva for 1 min and then centrifuged for 10 min at 1500 g. Glucose concentrations were determined using two methods: one based on an autoanalyzer using chemiluminescence assay and the other based on a biosensor using glucose oxidase enzyme-based amperometric method. A statistically significant correlation was found between the two methods (r = 0.802; p < 0.001). The most remarkable result from the data is that there were no significant differences in saliva glucose measurements between the two methods. This paper presents an innovative biosensor method that can be readily used in practice for rapid results, low cost, and specificity compared to the frequently used autoanalyzer method.

Biochemistry (Moscow) Supplement Series B Biomedical ChemistryVol. 18(4)
University of Cyprus (CY), Nevşehir Hacı Bektaş Veli University (TR), Teknoloji Arastirma ve Gelistirme Endustriyel Urunler Bilisim Teknolojileri San Tic (TR), University of Kyrenia (CY), University of Gothenburg (SE), Gazi University (TR)
Zero hunger
Openalex Percentile: Top 34%
Salivary Gland Disorders and Functions
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Saliva Glucose Determination by Biosensor: Method Comparison to Chemiluminescence Immunoassay — Umut Kökbaş, Rabia Şemsi, et al. · Biochemistry (Moscow) Supplement Series B Biomedical Chemistry (2024) | TGRS Research Map | TGRS