A High-Efficiency MHz-Integrated Three-Phase Interleaved Boost–<i>LLC</i> Converter With Voltage Regulation

Three-phase interleaved <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LLC</i> can achieve high-efficiency and low-ripple conversion, but it is difficult to reach a wide voltage regulation range due to the difficulty of synchronous rectification. Based on the principle of bridge arm multiplexing, this article proposes a three-phase interleaved boost and three-phase interleaved <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LLC</i> integrated topology. The integrated topology adopts a modulation strategy in which the duty and frequency change cooperatively, which can achieve decoupling of boost and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LLC</i> and smooth gain. Among them, the boost works in the forced continuous conduction mode, using the inductor current to realize zero-voltage turn-<sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> of all switching devices, which can realize an air-gap-free transformer design and help reduce winding losses. Based on the modal analysis, this article gives the switching function of the proposed topology to achieve synchronous rectification in the voltage regulation range. Furthermore, this article analyzes the effect of the transformer ratio on device stress and provides an optimization strategy for integrated transformers. Finally, a prototype with a switching frequency of 1 MHz, 40–60-V input, and 400-V at 1.5-kW output was designed to verify the proposed topology and the modulation strategy, achieving a full-load efficiency of 97.7% and a power density of 159 W/in<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup>.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-02-03
DOI
https://doi.org/10.1109/tpel.2025.3537657
Citations
2
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Efficiency MHz-Integrated Three-Phase Interleaved Boost–LLC Converter With Voltage Regulation

Yiyang Yan, Jiajia Guan, Jin Wen, Taseer Muhammad et al.
2 citations
IEEE Transactions on Power Electronics
Advanced DC-DC Converters
1.46
article

A High-Efficiency MHz-Integrated Three-Phase Interleaved Boost–LLC Converter With Voltage Regulation

Yiyang Yan, Jiajia Guan, Jin Wen, Taseer Muhammad, Shuangxi Zhu, Cai Chen, X. Sun, Yong Kang
article en
2 citations

Abstract

Three-phase interleaved <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LLC</i> can achieve high-efficiency and low-ripple conversion, but it is difficult to reach a wide voltage regulation range due to the difficulty of synchronous rectification. Based on the principle of bridge arm multiplexing, this article proposes a three-phase interleaved boost and three-phase interleaved <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LLC</i> integrated topology. The integrated topology adopts a modulation strategy in which the duty and frequency change cooperatively, which can achieve decoupling of boost and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LLC</i> and smooth gain. Among them, the boost works in the forced continuous conduction mode, using the inductor current to realize zero-voltage turn-<sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> of all switching devices, which can realize an air-gap-free transformer design and help reduce winding losses. Based on the modal analysis, this article gives the switching function of the proposed topology to achieve synchronous rectification in the voltage regulation range. Furthermore, this article analyzes the effect of the transformer ratio on device stress and provides an optimization strategy for integrated transformers. Finally, a prototype with a switching frequency of 1 MHz, 40–60-V input, and 400-V at 1.5-kW output was designed to verify the proposed topology and the modulation strategy, achieving a full-load efficiency of 97.7% and a power density of 159 W/in<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup>.

IEEE Transactions on Power ElectronicsVol. 40(6)
Huazhong University of Science and Technology (CN)
Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 20%
Advanced DC-DC Converters
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.