Development of Software for Diagnostics and Correction of Closed Orbit in the NICA Booster
The NICA (Nuclotron-based Ion Collider fAcility) accelerator complex consists of a collider and an injection complex. The injection complex of heavy ions includes ion source, linear accelerator, a 25 T m SC Booster synchrotron, a 38 T m SC synchrotron Nuclotron, and beam transfer lines. One of the main tasks in complex commissioning and tuning are the measurement and correction of the beam closed orbit. The software, written for orbit correction, was successfully tested during the commissioning runs. The paper describes the software and hardware developments for orbit measurement and correction.
Authors
- M. M. Shandov (ORCID: https://orcid.org/0000-0003-0095-8385)
- E. V. Gorbachev
- I. Yu. Nikolaichuk
- Valeri Lebedev (ORCID: https://orcid.org/0000-0003-3329-2831)
- G. S. Sedykh (ORCID: https://orcid.org/0000-0001-9778-462X)
- V. L. Smirnov (ORCID: https://orcid.org/0000-0001-8131-7816)
Institutions
- St Petersburg University (RU)
- Joint Institute for Nuclear Research (RU)
- Dubna State University (RU)
- National Research Nuclear University MEPhI (RU)
Publication Details
- Journal
- Instruments and Experimental Techniques
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1134/s0020441224701628
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00