Position-Sensitive Cherenkov Proton Beam Monitor
The results of a study of a new Cherenkov monitor of proton beams with a high pulsed current are presented. Good measurement agreement was obtained for the monitor, Gafchromic detector, and induction sensor for 160 MeV proton beam and pulsed average current 1 mA. Bench measurements of the coordinates of the position of the light flux simulating the light image of a proton beam in the radiator of a two-dimensional monitor were carried out. A comparative analysis of algorithms for reconstructing the coordinates of the light beam position with the results of monitor simulation is presented.
Authors
- Yu. K. Gavrilov (ORCID: https://orcid.org/0009-0004-5091-318X)
- С. В. Акулиничев (ORCID: https://orcid.org/0000-0002-9942-0974)
- R. Djilkibaev (ORCID: https://orcid.org/0000-0001-5132-9728)
Institutions
- Institute for Nuclear Research (RU)
- Russian Scientific Center of Surgery (RU)
Publication Details
- Journal
- Instruments and Experimental Techniques
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1134/s0020441224701446
- Primary Topic
- Radiation Therapy and Dosimetry
- Type
- article
- Field-Weighted Citation Impact
- 0.00