Estimating the Accuracy of Proton Beam Dosimetry with Film Detectors

The theoretical and experimental characteristics of depth dose distributions of protons in the Bragg peak region are investigated. Results of the Monte Carlo calculations in the TOPAS MC software package and experimental data obtained from film detectors and ionization chambers at the high-current proton linear accelerator of the Institute for Nuclear Research are used. The interrelationship between the results and the applicability of these detectors for measuring the absorbed dose are considered. The calculated dose distributions are in good agreement with the dose distributions measured using the ionization chambers for the pristine and spread-out Bragg peaks. Possible interrelationship between the linear energy transfer and the accuracy of dose measurements with the film detectors is shown. The discrepancy between the readings of the film detectors in the Bragg peak region, on the one hand, and the results of calculations and measurements with the ionization chambers, on the other hand, may be important for irradiation of biological samples, in particular, in the FLASH therapy modes.

Authors

Institutions

Publication Details

Journal
Instruments and Experimental Techniques
Published
2024-10-01
DOI
https://doi.org/10.1134/s0020441224701616
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating the Accuracy of Proton Beam Dosimetry with Film Detectors

С. В. Акулиничев, D. A. Kokontsev, G. V. Merzlikin, I. A. Yakovlev
Instruments and Experimental Techniques
Advanced Radiotherapy Techniques
article

Estimating the Accuracy of Proton Beam Dosimetry with Film Detectors

С. В. Акулиничев, D. A. Kokontsev, G. V. Merzlikin, I. A. Yakovlev
article en

Abstract

The theoretical and experimental characteristics of depth dose distributions of protons in the Bragg peak region are investigated. Results of the Monte Carlo calculations in the TOPAS MC software package and experimental data obtained from film detectors and ionization chambers at the high-current proton linear accelerator of the Institute for Nuclear Research are used. The interrelationship between the results and the applicability of these detectors for measuring the absorbed dose are considered. The calculated dose distributions are in good agreement with the dose distributions measured using the ionization chambers for the pristine and spread-out Bragg peaks. Possible interrelationship between the linear energy transfer and the accuracy of dose measurements with the film detectors is shown. The discrepancy between the readings of the film detectors in the Bragg peak region, on the one hand, and the results of calculations and measurements with the ionization chambers, on the other hand, may be important for irradiation of biological samples, in particular, in the FLASH therapy modes.

Instruments and Experimental TechniquesVol. 67(5)
Institute for Nuclear Research (RU), Medical Radiological Research Center (RU), Russian Scientific Center of Surgery (RU)
Affordable and clean energy
Openalex Percentile: Top 65%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.