Implementation of a Cellular Automaton for efficient simulations of atrial arrhythmias

In silico models offer a promising advancement for studying cardiac arrhythmias and their clinical implications. However, existing detailed mathematical models often suffer from prolonged computational time compared to diagnostic needs. This study introduces a Cellular Automaton (CA) model tailored to replicate atrial electrophysiology in different stages of Atrial Fibrillation (AF), including persistent AF (PsAF). The CA, using a finite set of states, has been trained using biophysical simulations on a reduced domain for a large set of pacing conditions. Fine-tuning included tissue heterogeneity and anisotropic propagation through pacing simulations. Characterized by Action Potential Duration (APD), Diastolic Interval (DI) and Conduction Velocity (CV) for varying levels of electrical remodeling, the biophysical simulations introduced restitution curves or surfaces into the CA. Validation involved a comprehensive comparison with realistic 2D and 3D atrial models, evaluating healthy and pro-arrhythmic behaviors. Comparisons between CA and biophysical solver revealed striking proximity, with a Cycle Length difference of <10 ms in self-sustained re-entry and a 4.66±0.57 ms difference in depolarization times across the complete atrial geometry. Notably, the CA model exhibited a 80% accuracy, 96% specificity and 45% sensitivity in predicting AF inducibility under different pacing sites and substrate conditions. Additionally, the CA allowed for a 64-fold decrease in computing time compared to the biophysical solver. CA emerges as an efficient and valid model for simulation of atrial electrophysiology across different stages of AF, with potential as a general screening tool for rapid tests. While biophysical tests are recommended for investigating specific mechanisms, CA proves valuable in clinical applications for personalized therapy planning through digital twin simulations.

Authors

Institutions

Publication Details

Journal
Medical Image Analysis
Published
2025-02-03
DOI
https://doi.org/10.1016/j.media.2025.103484
Citations
4
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
5.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of a Cellular Automaton for efficient simulations of atrial arrhythmias

Miguel Lozano, Pau Romero, Ignacio García‐Fernández, David Calvo et al.
4 citations
Medical Image Analysis
Cardiac electrophysiology and arrhythmias
5.55
article

Implementation of a Cellular Automaton for efficient simulations of atrial arrhythmias

Miguel Lozano, Pau Romero, Ignacio García‐Fernández, David Calvo, Giada Sira Romitti, Alejandro Liberos, Miguel Rodrigo, Rafael Sebastián, María Termenón-Rivas, Dolors Serra, Javier Barrios-Álvarez de Arcaya
article en
4 citations

Abstract

In silico models offer a promising advancement for studying cardiac arrhythmias and their clinical implications. However, existing detailed mathematical models often suffer from prolonged computational time compared to diagnostic needs. This study introduces a Cellular Automaton (CA) model tailored to replicate atrial electrophysiology in different stages of Atrial Fibrillation (AF), including persistent AF (PsAF). The CA, using a finite set of states, has been trained using biophysical simulations on a reduced domain for a large set of pacing conditions. Fine-tuning included tissue heterogeneity and anisotropic propagation through pacing simulations. Characterized by Action Potential Duration (APD), Diastolic Interval (DI) and Conduction Velocity (CV) for varying levels of electrical remodeling, the biophysical simulations introduced restitution curves or surfaces into the CA. Validation involved a comprehensive comparison with realistic 2D and 3D atrial models, evaluating healthy and pro-arrhythmic behaviors. Comparisons between CA and biophysical solver revealed striking proximity, with a Cycle Length difference of <10 ms in self-sustained re-entry and a 4.66±0.57 ms difference in depolarization times across the complete atrial geometry. Notably, the CA model exhibited a 80% accuracy, 96% specificity and 45% sensitivity in predicting AF inducibility under different pacing sites and substrate conditions. Additionally, the CA allowed for a 64-fold decrease in computing time compared to the biophysical solver. CA emerges as an efficient and valid model for simulation of atrial electrophysiology across different stages of AF, with potential as a general screening tool for rapid tests. While biophysical tests are recommended for investigating specific mechanisms, CA proves valuable in clinical applications for personalized therapy planning through digital twin simulations.

Medical Image AnalysisVol. 101
Universitat de València (ES), Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (ES)
Generalitat Valenciana, Agencia Estatal de Investigación
Openalex Percentile: Top 5%
Cardiac electrophysiology and arrhythmias
5.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.