Dynamic characteristics of a two-phase mechanically pumped cooling loop for avionics

Given the varying flight conditions and mission requirements that affect aircraft cold sources and heat loads, it is crucial to investigate the dynamic behavior of a two-phase mechanically pumped cooling loop (MPCL) for avionics. Here, an experimental MPCL system charged with R134a was established, and its performance was evaluated under cold source temperatures of 16–46 °C and heat fluxes of 50–150 kW/m 2 . When the cold source temperature varies, the heating wall temperature and pressure drop are 33.7–60.0 °C and 78.0−119.6 kPa for unadjustable pump mode, and they are 34.1–60.0 °C and 59.6−124.6 kPa for adjustable pump mode. When heat load starts, the heating wall temperature and pressure drop rapid rise, and then stabilize. For low temperature start-up, the heating wall temperature is lower, but the pressure drop is usually higher compared to high temperature start-up. When heat load jumps, heating wall temperature and pressure drop rise and then stabilize regardless of pump mode. The pump mode has a minor impact on the heating wall temperature, but the pressure drop is greater in adjustable mode than in unadjustable mode. The findings indicate the designed MPCL can always tend to be stable when the cold source or heat load change.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-02-04
DOI
https://doi.org/10.1016/j.csite.2025.105830
Citations
5
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
3.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic characteristics of a two-phase mechanically pumped cooling loop for avionics

Jiale Wang, Zhaohao Xu, Yu Xu, S. Qi
5 citations
Case Studies in Thermal Engineering
Refrigeration and Air Conditioning Technologies
3.57
article

Dynamic characteristics of a two-phase mechanically pumped cooling loop for avionics

Jiale Wang, Zhaohao Xu, Yu Xu, S. Qi
article en
5 citations

Abstract

Given the varying flight conditions and mission requirements that affect aircraft cold sources and heat loads, it is crucial to investigate the dynamic behavior of a two-phase mechanically pumped cooling loop (MPCL) for avionics. Here, an experimental MPCL system charged with R134a was established, and its performance was evaluated under cold source temperatures of 16–46 °C and heat fluxes of 50–150 kW/m 2 . When the cold source temperature varies, the heating wall temperature and pressure drop are 33.7–60.0 °C and 78.0−119.6 kPa for unadjustable pump mode, and they are 34.1–60.0 °C and 59.6−124.6 kPa for adjustable pump mode. When heat load starts, the heating wall temperature and pressure drop rapid rise, and then stabilize. For low temperature start-up, the heating wall temperature is lower, but the pressure drop is usually higher compared to high temperature start-up. When heat load jumps, heating wall temperature and pressure drop rise and then stabilize regardless of pump mode. The pump mode has a minor impact on the heating wall temperature, but the pressure drop is greater in adjustable mode than in unadjustable mode. The findings indicate the designed MPCL can always tend to be stable when the cold source or heat load change.

Case Studies in Thermal EngineeringVol. 67
Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Aeronautical Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 8%
Refrigeration and Air Conditioning Technologies
3.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.