Response control of multi-storied adjacent buildings using double-compliant liquid dampers-inerter subjected to seismic excitations

Pounding between adjacent, closely spaced buildings was frequently observed in previous major seismic events. This paper proposes a novel double-compliant liquid dampers-inerter (DCLDI) system to mitigate the potential pounding and response of adjacent multi-storied buildings under seismic excitations. Specifically, three configurations of DCLDI are investigated. In Configuration 1, two compliant liquid dampers (CLDs) are linked by the inerter; in Configuration 2, one end of the inerter is connected to the roof of Building 1, while the other end is connected to the CLD, placed at the roof of Building 2; in Configuration 3, one end of the inerter is connected to the CLD, placed at the roof of Building 1, while the other end is connected to the roof of Building 2. Two example benchmark buildings, 4-story and 5-story are taken up for numerical demonstration. The mathematical modelling of the adjacent buildings is done with the shear building multi-degree-of-freedom (MDOF) approximation. The control effectiveness of the proposed damper configurations is investigated in both time and frequency domains. Five parameters of DCLDI are optimized using a single-objective optimization solver, ‘ ga ’ in MATLAB. The ratio of the relative total energy of the controlled and uncontrolled buildings is chosen as an objective function, while white noise is considered as seismic input. For time domain analysis, 40 recorded seismic ground motions, 20 far-fault, and 20 near-fault are chosen. It is noticed that the optimum DCLDI achieves a maximum reduction in peak acceleration up to 25.3 % for Building 1 and 22.5 % for Building 2, respectively. While DCLDI fails to significantly reduce the maximum inter-story drift ratios and peak displacements, especially in Building 1, under individual earthquakes, the average percentage reductions of the peak responses are modest. • A novel double-compliant liquid damper-inerter (DCLDI) system is proposed. • Optimization using the Genetic algorithm under White Gaussian Noise excitation. • Frequency domain analysis for different soil conditions under Kanai-Tajimi spectrum. • Time domain analysis under 40 recorded seismic ground motions. • Optimally designed DCLDI efficiently controls structural responses of adjacent buildings.

Authors

Publication Details

Journal
Soil Dynamics and Earthquake Engineering
Published
2025-02-03
DOI
https://doi.org/10.1016/j.soildyn.2025.109276
Citations
6
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
5.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Response control of multi-storied adjacent buildings using double-compliant liquid dampers-inerter subjected to seismic excitations

Anupam Das
6 citations
Soil Dynamics and Earthquake Engineering
Vibration Control and Rheological Fluids
5.72
article

Response control of multi-storied adjacent buildings using double-compliant liquid dampers-inerter subjected to seismic excitations

Anupam Das
article en
6 citations

Abstract

Pounding between adjacent, closely spaced buildings was frequently observed in previous major seismic events. This paper proposes a novel double-compliant liquid dampers-inerter (DCLDI) system to mitigate the potential pounding and response of adjacent multi-storied buildings under seismic excitations. Specifically, three configurations of DCLDI are investigated. In Configuration 1, two compliant liquid dampers (CLDs) are linked by the inerter; in Configuration 2, one end of the inerter is connected to the roof of Building 1, while the other end is connected to the CLD, placed at the roof of Building 2; in Configuration 3, one end of the inerter is connected to the CLD, placed at the roof of Building 1, while the other end is connected to the roof of Building 2. Two example benchmark buildings, 4-story and 5-story are taken up for numerical demonstration. The mathematical modelling of the adjacent buildings is done with the shear building multi-degree-of-freedom (MDOF) approximation. The control effectiveness of the proposed damper configurations is investigated in both time and frequency domains. Five parameters of DCLDI are optimized using a single-objective optimization solver, ‘ ga ’ in MATLAB. The ratio of the relative total energy of the controlled and uncontrolled buildings is chosen as an objective function, while white noise is considered as seismic input. For time domain analysis, 40 recorded seismic ground motions, 20 far-fault, and 20 near-fault are chosen. It is noticed that the optimum DCLDI achieves a maximum reduction in peak acceleration up to 25.3 % for Building 1 and 22.5 % for Building 2, respectively. While DCLDI fails to significantly reduce the maximum inter-story drift ratios and peak displacements, especially in Building 1, under individual earthquakes, the average percentage reductions of the peak responses are modest. • A novel double-compliant liquid damper-inerter (DCLDI) system is proposed. • Optimization using the Genetic algorithm under White Gaussian Noise excitation. • Frequency domain analysis for different soil conditions under Kanai-Tajimi spectrum. • Time domain analysis under 40 recorded seismic ground motions. • Optimally designed DCLDI efficiently controls structural responses of adjacent buildings.

Soil Dynamics and Earthquake EngineeringVol. 191
Sustainable cities and communities
Openalex Percentile: Top 5%
Vibration Control and Rheological Fluids
5.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.