Biomechanical stability and stress distribution in intertrochanteric fracture of femur fixation by Titanium Alloy (Ti-6Al-4 V) nailing systems according to fracture reduction: A finite element analysis

• Tip-apex distance (TAD) controlled intertrochanteric fracture models were designed, and their biomechanical performance after intramedullary nailing systems was thoroughly evaluated, focusing on stress distribution and displacement under walking and stair climbing conditions. • Intramedullary models, especially subtype P, showed increased stress and displacement, revealing a higher risk for implant failure, suggesting a need for careful reduction planning in clinical practice. • These findings provide valuable insight into precise reduction techniques to minimize stress concentrations and improve long-term implant stability, particularly in challenging postoperative conditions. This study examines the biomechanical effectiveness of treating femoral intertrochanteric fractures using intramedullary nailing systems, assessing how stress distribution and displacement vary during walking and stair-climbing activities. Finite element analysis was employed to analyze different types of reductions, concentrating on anatomical, intramedullary, and extramedullary configurations, along with subtypes N, A, and P. The results indicated that anatomical reduction models, particularly subtypes N and A, consistently demonstrated better biomechanical stability, characterized by lower von Mises stress and enhanced load distribution. Conversely, intramedullary models, particularly subtype P, showed higher stress and displacement, which suggests greater risks for implant failure. These results offer important insights into factors reliant on the surgeon's technique, implying that refining reduction methods could significantly reduce stress and displacement during dynamic activities, thus lowering the likelihood of complications like implant failure.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-02-03
DOI
https://doi.org/10.1016/j.rineng.2025.104202
Citations
4
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
8.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical stability and stress distribution in intertrochanteric fracture of femur fixation by Titanium Alloy (Ti-6Al-4 V) nailing systems according to fracture reduction: A finite element analysis

Soonchul Lee, Il Won Suh, Seong‐Eun Byun
4 citations
Results in Engineering
Hip and Femur Fractures
8.03
article

Biomechanical stability and stress distribution in intertrochanteric fracture of femur fixation by Titanium Alloy (Ti-6Al-4 V) nailing systems according to fracture reduction: A finite element analysis

Soonchul Lee, Il Won Suh, Seong‐Eun Byun
article en
4 citations

Abstract

• Tip-apex distance (TAD) controlled intertrochanteric fracture models were designed, and their biomechanical performance after intramedullary nailing systems was thoroughly evaluated, focusing on stress distribution and displacement under walking and stair climbing conditions. • Intramedullary models, especially subtype P, showed increased stress and displacement, revealing a higher risk for implant failure, suggesting a need for careful reduction planning in clinical practice. • These findings provide valuable insight into precise reduction techniques to minimize stress concentrations and improve long-term implant stability, particularly in challenging postoperative conditions. This study examines the biomechanical effectiveness of treating femoral intertrochanteric fractures using intramedullary nailing systems, assessing how stress distribution and displacement vary during walking and stair-climbing activities. Finite element analysis was employed to analyze different types of reductions, concentrating on anatomical, intramedullary, and extramedullary configurations, along with subtypes N, A, and P. The results indicated that anatomical reduction models, particularly subtypes N and A, consistently demonstrated better biomechanical stability, characterized by lower von Mises stress and enhanced load distribution. Conversely, intramedullary models, particularly subtype P, showed higher stress and displacement, which suggests greater risks for implant failure. These results offer important insights into factors reliant on the surgeon's technique, implying that refining reduction methods could significantly reduce stress and displacement during dynamic activities, thus lowering the likelihood of complications like implant failure.

Results in EngineeringVol. 25
CHA University Bundang Medical Center (KR), CHA University (KR), Jeonbuk National University (KR)
Openalex Percentile: Top 3%
Hip and Femur Fractures
8.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines