Probing soft X-ray induced photoreduction of a model Mn-complex at cryogenic conditions

Soft X-ray absorption spectroscopy of first row transition elements at their respective L-edges provides important information about the oxidation and spin states of the metal centers. However, the associated sample damage in radiation-sensitive samples substantially alters the electronic and chemical structures of redox-active metal centers. Here, we measure the soft X-ray spectrum of the model Mn<sup>III</sup>(acac)<sub>3</sub> complex containing a redox-active Mn<sup>III</sup> metal center in an octahedral environment with a superconducting transition-edge sensor detector. To reduce the secondary damage resulting primarily from the diffusion of radicals and electrons, the spectra are collected at 30 K and 80 K on solid samples. Starting from the first scan, we detect the contribution of X-ray induced sample damage leading to a change in the Mn<sup>II</sup> intensity. However, at low temperatures, particularly at 30 K, we do not observe a gradual increase in the radiation damage with successive scans with the X-ray beam at the same spot. At our estimated dose of 90 kGy, we find 62% of Mn<sup>III</sup>(acac)<sub>3</sub> is still intact at 30 K. However, at room temperature, we see a gradual increase in radiation damage with increasing numbers of scans at the same spot, which is consistent with the possibility of increased diffusion rates of secondary radicals and electrons as noted in other studies.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2025-02-03
DOI
https://doi.org/10.1107/s1600577524012189
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Probing soft X-ray induced photoreduction of a model Mn-complex at cryogenic conditions

Jan F Kern, Charles J. Titus, Margaret Doyle, Vittal K. Yachandra et al.
Journal of Synchrotron Radiation
X-ray Spectroscopy and Fluorescence Analysis
article

Probing soft X-ray induced photoreduction of a model Mn-complex at cryogenic conditions

Jan F Kern, Charles J. Titus, Margaret Doyle, Vittal K. Yachandra, Li‐Ta Kao, Kuntal Chatterjee, Stephen R. Leone, Philippe Wernet, Junko Yano, Sang‐Jun Lee
article en

Abstract

Soft X-ray absorption spectroscopy of first row transition elements at their respective L-edges provides important information about the oxidation and spin states of the metal centers. However, the associated sample damage in radiation-sensitive samples substantially alters the electronic and chemical structures of redox-active metal centers. Here, we measure the soft X-ray spectrum of the model Mn<sup>III</sup>(acac)<sub>3</sub> complex containing a redox-active Mn<sup>III</sup> metal center in an octahedral environment with a superconducting transition-edge sensor detector. To reduce the secondary damage resulting primarily from the diffusion of radicals and electrons, the spectra are collected at 30 K and 80 K on solid samples. Starting from the first scan, we detect the contribution of X-ray induced sample damage leading to a change in the Mn<sup>II</sup> intensity. However, at low temperatures, particularly at 30 K, we do not observe a gradual increase in the radiation damage with successive scans with the X-ray beam at the same spot. At our estimated dose of 90 kGy, we find 62% of Mn<sup>III</sup>(acac)<sub>3</sub> is still intact at 30 K. However, at room temperature, we see a gradual increase in radiation damage with increasing numbers of scans at the same spot, which is consistent with the possibility of increased diffusion rates of secondary radicals and electrons as noted in other studies.

Journal of Synchrotron RadiationVol. 32(2)
Uppsala University (SE), National Institute of Standards and Technology (US), Lawrence Berkeley National Laboratory (US), SLAC National Accelerator Laboratory (US), University of California, Berkeley (US)
U.S. Department of Energy, Deutsche Forschungsgemeinschaft, National Institutes of Health, Office of Science, National Institute of General Medical Sciences, Basic Energy Sciences, SLAC National Accelerator Laboratory
Openalex Percentile: Top 98%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.