Highly selective and sensitive detection of atorvastatin from using a MIP-based electrochemical sensor

Atorvastatin (ATR) is one of the statins that are widely used all around the world. This study presents a molecularly imprinted polymer (MIP) based electrochemical sensor for the sensitive and selective detection of ATR in binary mixtures and commercial serum samples. The designed sensor was fabricated using a photopolymerization (PP) approach on a glassy carbon electrode (GCE) using ATR as the template and acrylamide (ACR) as the functional monomer. The developed ATR/ACR@MIP-GCE sensor was evaluated electrochemically and morphologically using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM). The indirect measuring method was used with a 5.0 mM [Fe(CN) 6 ] 3–/4– solution to determine the ATR in the linear range of 1.0–10.0 pM. Moreover, the sensor demonstrated excellent linearity and extremely sensitive quantification (LOQ) limit of detection (LOD) values in both biological media and standard solutions. It also performed well in terms of specificity by effectively differentiating ATR from compounds with similar structures. Excellent repeatability and reproducibility results have confirmed the reliability of the sensor. The selectivity of the ATR/ACR@MIP-GCE sensor for ATR was proven by interference studies on ezetimibe and their binary mixtures.

Authors

Institutions

Publication Details

Journal
Journal of Pharmaceutical and Biomedical Analysis Open
Published
2025-02-03
DOI
https://doi.org/10.1016/j.jpbao.2025.100061
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly selective and sensitive detection of atorvastatin from using a MIP-based electrochemical sensor

E. Pìşkin, Ahmet Çetinkaya, Síbel A. Özkan, Fatih Ahmet Korkut
3 citations
Journal of Pharmaceutical and Biomedical Analysis Open
Electrochemical sensors and biosensors
2.19
article

Highly selective and sensitive detection of atorvastatin from using a MIP-based electrochemical sensor

E. Pìşkin, Ahmet Çetinkaya, Síbel A. Özkan, Fatih Ahmet Korkut
article en
3 citations

Abstract

Atorvastatin (ATR) is one of the statins that are widely used all around the world. This study presents a molecularly imprinted polymer (MIP) based electrochemical sensor for the sensitive and selective detection of ATR in binary mixtures and commercial serum samples. The designed sensor was fabricated using a photopolymerization (PP) approach on a glassy carbon electrode (GCE) using ATR as the template and acrylamide (ACR) as the functional monomer. The developed ATR/ACR@MIP-GCE sensor was evaluated electrochemically and morphologically using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM). The indirect measuring method was used with a 5.0 mM [Fe(CN) 6 ] 3–/4– solution to determine the ATR in the linear range of 1.0–10.0 pM. Moreover, the sensor demonstrated excellent linearity and extremely sensitive quantification (LOQ) limit of detection (LOD) values in both biological media and standard solutions. It also performed well in terms of specificity by effectively differentiating ATR from compounds with similar structures. Excellent repeatability and reproducibility results have confirmed the reliability of the sensor. The selectivity of the ATR/ACR@MIP-GCE sensor for ATR was proven by interference studies on ezetimibe and their binary mixtures.

Journal of Pharmaceutical and Biomedical Analysis OpenVol. 5
Ankara University (TR), Hacettepe University (TR)
Openalex Percentile: Top 14%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.