Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection

The rapid rise of label-free biosensing technologies has led to multiple creative strategies for the detection of macromolecules in complex biological solutions for disease state monitoring, drug discovery, and basic science research. A challenge with these techniques is that assays conducted in complex media such as serum suffer from nonspecific binding of matrix constituents. In label-free biosensors, it is virtually impossible to distinguish these nonspecific interactions without the use of a reference (negative control) probe. Only with reference subtraction can the specific binding signal be faithfully reported. To date, this has been a sparsely studied area in the biosensing field. Here, we report an FDA-inspired framework for optimum control probe selection and a systematic analysis for determining the optimal negative control probe given two monoclonal antibody capture probes on photonic ring resonator sensors. Briefly, while the differences in assay performance for IL-17A and CRP were found to be subtle, the best-scoring reference control based on the bioanalytical parameters of linearity, accuracy, and selectivity differed for each analyte. In the IL-17A assay, BSA scored the highest at 83%, while mouse IgG1 isotype control antibody placed a close second with 75%. With respect to the CRP assay, the rat IgG1 isotype control antibody scored the highest at 95%, while anti-FITC scored the second highest at 89%. These results suggest that although isotype-matching to the capture antibody may be tempting, the best on-chip reference control must be optimized on a case-by-case basis using the framework we report.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-02-03
DOI
https://doi.org/10.1021/acs.analchem.4c05854
Citations
6
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection

Joseph Bucukovski, Benjamin L. Miller
6 citations
Analytical Chemistry
Photonic and Optical Devices
4.38
article

Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection

Joseph Bucukovski, Benjamin L. Miller
article en
6 citations

Abstract

The rapid rise of label-free biosensing technologies has led to multiple creative strategies for the detection of macromolecules in complex biological solutions for disease state monitoring, drug discovery, and basic science research. A challenge with these techniques is that assays conducted in complex media such as serum suffer from nonspecific binding of matrix constituents. In label-free biosensors, it is virtually impossible to distinguish these nonspecific interactions without the use of a reference (negative control) probe. Only with reference subtraction can the specific binding signal be faithfully reported. To date, this has been a sparsely studied area in the biosensing field. Here, we report an FDA-inspired framework for optimum control probe selection and a systematic analysis for determining the optimal negative control probe given two monoclonal antibody capture probes on photonic ring resonator sensors. Briefly, while the differences in assay performance for IL-17A and CRP were found to be subtle, the best-scoring reference control based on the bioanalytical parameters of linearity, accuracy, and selectivity differed for each analyte. In the IL-17A assay, BSA scored the highest at 83%, while mouse IgG1 isotype control antibody placed a close second with 75%. With respect to the CRP assay, the rat IgG1 isotype control antibody scored the highest at 95%, while anti-FITC scored the second highest at 89%. These results suggest that although isotype-matching to the capture antibody may be tempting, the best on-chip reference control must be optimized on a case-by-case basis using the framework we report.

Analytical ChemistryVol. 97(6)
Instituto de Óptica "Daza de Valdés" (ES), University of Rochester (US)
National Institutes of Health, National Center for Advancing Translational Sciences
Openalex Percentile: Top 6%
Photonic and Optical Devices
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.