An overview of the recent developments in biodegradable Mg-Zn alloy

• Critical review of Mg-Zn alloy for biomedical application. • Mg-(4.0–5.0) wt.% Zn alloy showed the highest strength and the lowest corrosion rate. • Achieved strength and corrosion rate still does not meet the desired requirement. • Corrosion can be further lower by thermomechanical and composite coating process. • More elucidation of biological response including in vitro and in vivo studies. The increasing interest in Mg-Zn binary alloys as temporary implant materials is attributed to their outstanding biocompatibility, biodegradability, and favourable mechanical properties. However, their application is constrained by high degradation rates in the physiological environment, resulting in the release of hydrogen gas and a rapid decline in mechanical properties. Additionally, the material's biocompatibility is contingent upon its degradability. Researchers have demonstrated that addressing these issues is possible through strategies such as controlling Zn content, employing thermo-mechanical processing to achieve suitable microstructures, and applying surface coatings. This manuscript provides a comprehensive review of published literature on Mg-Zn alloys, exploring the challenges and outlining future research directions in this field.

Authors

Institutions

Publication Details

Journal
Journal of Magnesium and Alloys
Published
2025-02-01
DOI
https://doi.org/10.1016/j.jma.2025.01.011
Citations
31
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
18.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An overview of the recent developments in biodegradable Mg-Zn alloy

Akiko Yamamoto, Manas Ranjan Sahu
31 citations
Journal of Magnesium and Alloys
Magnesium Alloys: Properties and Applications
18.51
article

An overview of the recent developments in biodegradable Mg-Zn alloy

Akiko Yamamoto, Manas Ranjan Sahu
article en
31 citations

Abstract

• Critical review of Mg-Zn alloy for biomedical application. • Mg-(4.0–5.0) wt.% Zn alloy showed the highest strength and the lowest corrosion rate. • Achieved strength and corrosion rate still does not meet the desired requirement. • Corrosion can be further lower by thermomechanical and composite coating process. • More elucidation of biological response including in vitro and in vivo studies. The increasing interest in Mg-Zn binary alloys as temporary implant materials is attributed to their outstanding biocompatibility, biodegradability, and favourable mechanical properties. However, their application is constrained by high degradation rates in the physiological environment, resulting in the release of hydrogen gas and a rapid decline in mechanical properties. Additionally, the material's biocompatibility is contingent upon its degradability. Researchers have demonstrated that addressing these issues is possible through strategies such as controlling Zn content, employing thermo-mechanical processing to achieve suitable microstructures, and applying surface coatings. This manuscript provides a comprehensive review of published literature on Mg-Zn alloys, exploring the challenges and outlining future research directions in this field.

Journal of Magnesium and AlloysVol. 13(2)
National Institute for Materials Science (JP)
Openalex Percentile: Top 0%
Magnesium Alloys: Properties and Applications
18.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.