Evaluation Of Air Polishing Effect on Implant Surface at Three Different Defect Angulations

Aim:The aim of this in vitro study is to evaluation of air polishing effects on implant surfaces at three different defect angulations Material and methods: The present study is performed using three titanium SLA-activated implants.Around One implant, 30angulation bone defects were created in the model, the second implant had a 60angulated bone defect, and 90 angulated bone defects were made for the third implant.All three implants were surface-treated with erythritol powder air-polishing, and the defect wall was taken as reference angulation.Alterations in the surface morphology were assessed using scanning electron micrographs (SEM) and alterations in the surface composition were assesses using EDX.Results: After treatment with air-polishing, SEM images showed no significant alterations on machined implant surfaces.Air polishing resulted in slight smoothing of the machined rings, indicating minimal surface modification in implant 3. Elevation in the levels of titanium and aluminium after air polishing was estimated using EDX analysis Conclusion: Every SEM image confirms the implant system's distinct surface topography.Cleaning with air-polishing devices did not result in considerable surface deterioration.

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2024-12-24
DOI
https://doi.org/10.53555/ajbr.v27i4s.5411
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation Of Air Polishing Effect on Implant Surface at Three Different Defect Angulations

Neeraja Gajula
African Journal of Biomedical Research
Dental materials and restorations
article

Evaluation Of Air Polishing Effect on Implant Surface at Three Different Defect Angulations

Neeraja Gajula
article en

Abstract

Aim:The aim of this in vitro study is to evaluation of air polishing effects on implant surfaces at three different defect angulations Material and methods: The present study is performed using three titanium SLA-activated implants.Around One implant, 30angulation bone defects were created in the model, the second implant had a 60angulated bone defect, and 90 angulated bone defects were made for the third implant.All three implants were surface-treated with erythritol powder air-polishing, and the defect wall was taken as reference angulation.Alterations in the surface morphology were assessed using scanning electron micrographs (SEM) and alterations in the surface composition were assesses using EDX.Results: After treatment with air-polishing, SEM images showed no significant alterations on machined implant surfaces.Air polishing resulted in slight smoothing of the machined rings, indicating minimal surface modification in implant 3. Elevation in the levels of titanium and aluminium after air polishing was estimated using EDX analysis Conclusion: Every SEM image confirms the implant system's distinct surface topography.Cleaning with air-polishing devices did not result in considerable surface deterioration.

African Journal of Biomedical Research
Openalex Percentile: Top 70%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.