Multiple Cell Array Detector for a Heavy Ion Beam Probe on the T-15MD Tokamak

The potential of utilizing a multiple cell array detector (MCAD) [8] has been demonstrated as an additional tool for correlation studies of density and poloidal field fluctuations in a plasma as a part of the heavy ion beam probe on the T-15MD tokamak. The optimum position and size of the MCAD have been found, and its cell size has been determined. Trajectories of probing particles have been calculated and the plasma region for measurements has been estimated for the toroidal magnetic fields BT = 1.2, 1.5, 1.7, and 2.0 T. It has been shown that simultaneous measurements with the MCAD and the energy analyzer as the main measurement tool are possible, which allows the study of radial and poloidal spatial correlations of medium scale comparable to the small plasma radius. The spatial resolution of measurements and attenuation of the beam current signal during its passage through the plasma have been estimated.

Authors

Institutions

Publication Details

Journal
Physics of Atomic Nuclei
Published
2024-12-01
DOI
https://doi.org/10.1134/s1063778824090448
Citations
1
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple Cell Array Detector for a Heavy Ion Beam Probe on the T-15MD Tokamak

Е. А. Vinitskiy, L.G. Eliseev, A. V. Melnikov, O. D. Krohalev
1 citations
Physics of Atomic Nuclei
Magnetic confinement fusion research
0.66
article

Multiple Cell Array Detector for a Heavy Ion Beam Probe on the T-15MD Tokamak

Е. А. Vinitskiy, L.G. Eliseev, A. V. Melnikov, O. D. Krohalev
article en
1 citations

Abstract

The potential of utilizing a multiple cell array detector (MCAD) [8] has been demonstrated as an additional tool for correlation studies of density and poloidal field fluctuations in a plasma as a part of the heavy ion beam probe on the T-15MD tokamak. The optimum position and size of the MCAD have been found, and its cell size has been determined. Trajectories of probing particles have been calculated and the plasma region for measurements has been estimated for the toroidal magnetic fields BT = 1.2, 1.5, 1.7, and 2.0 T. It has been shown that simultaneous measurements with the MCAD and the energy analyzer as the main measurement tool are possible, which allows the study of radial and poloidal spatial correlations of medium scale comparable to the small plasma radius. The spatial resolution of measurements and attenuation of the beam current signal during its passage through the plasma have been estimated.

Physics of Atomic NucleiVol. 87(9)
Moscow Institute of Physics and Technology (RU), Moscow Power Engineering Institute (RU), Kurchatov Institute (RU), Moscow Aviation Institute (RU), National Research Nuclear University MEPhI (RU)
Affordable and clean energy
Openalex Percentile: Top 13%
Magnetic confinement fusion research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.