Advanced LC-MS/MS method for selective quantification of nitrosamine impurities in Risperidone: Enhancing drug safety

• Development and validation: a robust LC-MS/MS method was developed and validated for the precise quantification of nitrosamine impurities in risperidone drug substances. • Method optimization: critical parameters were optimized to ensure high selectivity and sensitivity for detecting trace-level nitrosamines. • Enhanced drug safety: the method enables reliable identification and quantification of potential carcinogenic impurities, reinforcing patient safety. • Application to marketed samples: analysis of commercial risperidone samples revealed variability in nitrosamine levels, highlighting the necessity for routine monitoring. • Quality control implications: this study emphasizes the importance of stringent regulatory standards and enhanced quality control measures in pharmaceutical manufacturing. In the current study, a simple, rapid, and sensitive analytical method was developed and validated for the determination and quantification of four nitrosamine drug substance-related impurities (NDSRIs) in Risperidone drug substance. Chromatographic separation was achieved on an ACE-5 PFP C18 column (150 mm × 4.6 mm × 3 µm) using gradient elution with 0.2 % formic acid and methanol. The method utilized a flow rate of 0.8 mL/min, an injection volume of 5 µL, and a column temperature of 40 °C. Positive electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode was used for quantification. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.12 to 0.46 and 0.23–0.93 µg/mL, respectively. The calibration curves for NDIRs impurities (0.23–185.72 µg/mL) exhibited R² values between 0.998 and 0.999. Recoveries ranged varied from 94.9 to 124.4 %, with % RSD < 15.0 %. The results indicated that the method is reliable for monitoring all NINA, NBOP, NBP, and NB impurities in Risperidone.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2025-02-01
DOI
https://doi.org/10.1016/j.talo.2025.100416
Citations
5
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
3.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced LC-MS/MS method for selective quantification of nitrosamine impurities in Risperidone: Enhancing drug safety

Bhavin Dhaduk, Pankajkumar B. Nariya, Hitesh Thumbar
5 citations
Talanta Open
Analytical Chemistry and Chromatography
3.78
article

Advanced LC-MS/MS method for selective quantification of nitrosamine impurities in Risperidone: Enhancing drug safety

Bhavin Dhaduk, Pankajkumar B. Nariya, Hitesh Thumbar
article en
5 citations

Abstract

• Development and validation: a robust LC-MS/MS method was developed and validated for the precise quantification of nitrosamine impurities in risperidone drug substances. • Method optimization: critical parameters were optimized to ensure high selectivity and sensitivity for detecting trace-level nitrosamines. • Enhanced drug safety: the method enables reliable identification and quantification of potential carcinogenic impurities, reinforcing patient safety. • Application to marketed samples: analysis of commercial risperidone samples revealed variability in nitrosamine levels, highlighting the necessity for routine monitoring. • Quality control implications: this study emphasizes the importance of stringent regulatory standards and enhanced quality control measures in pharmaceutical manufacturing. In the current study, a simple, rapid, and sensitive analytical method was developed and validated for the determination and quantification of four nitrosamine drug substance-related impurities (NDSRIs) in Risperidone drug substance. Chromatographic separation was achieved on an ACE-5 PFP C18 column (150 mm × 4.6 mm × 3 µm) using gradient elution with 0.2 % formic acid and methanol. The method utilized a flow rate of 0.8 mL/min, an injection volume of 5 µL, and a column temperature of 40 °C. Positive electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode was used for quantification. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.12 to 0.46 and 0.23–0.93 µg/mL, respectively. The calibration curves for NDIRs impurities (0.23–185.72 µg/mL) exhibited R² values between 0.998 and 0.999. Recoveries ranged varied from 94.9 to 124.4 %, with % RSD < 15.0 %. The results indicated that the method is reliable for monitoring all NINA, NBOP, NBP, and NB impurities in Risperidone.

Talanta OpenVol. 11
RK University (IN), Atmiya University (IN)
Good health and well-being
Openalex Percentile: Top 7%
Analytical Chemistry and Chromatography
3.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.