Pressurized liquid extraction and GC/MS determination of model contaminants in HDPE - Application to recycling of post-consumer polyolefins using limonene

A pressurized liquid extraction and gas chromatography-mass spectrometry (PLE-GC/MS) method is developed for the quantification of seven model contaminants in post-consumer and recycled high-density polyethylene (HDPE). Chloroform, toluene, chlorobenzene, methyl salicylate, phenyl cyclohexane, benzophenone, and methyl stearate were selected as model contaminants according to the European Food Safety Authority (EFSA) and the Food and Drug Administration (FDA) recommendations. The GC/MS method presented limits of detection (LOD) under 0.5 µg L<sup>-1</sup> for all contaminants except toluene and methyl stearate (18 µg L<sup>-1</sup> and 310 µg L<sup>-1</sup> respectively). Repeatability and intermediate precision were studied at two concentration levels, with the former presenting relative standard deviations under 10 % and the latter under 17 % in almost all cases. The PLE method was optimized by means of a central composite design (CCD), studying the extraction temperature and time. The selected conditions were three extraction cycles with acetone at 100 °C for 6 min at 1500 psi. Accuracy, repeatability and intermediate precision were stablished for the whole PLE-GC/MS method. Accuracy values were close to 100 % for most of them. Repeatability and intermediate precision were good for most of the model contaminants, with RSD values less than 11 and 17 %, respectively. The PLE-GC/MS method was applied to evaluate, via a challenge test, a novel HDPE recycling method based on the dissolution and precipitation of the polymer using limonene. The recycling method was shown to have high cleaning efficiencies, proving its potential in recycling of HDPE, as well as the utility of the PLE-GC/MS method to carry out challenge test evaluations.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2025-02-01
DOI
https://doi.org/10.1016/j.chroma.2025.465749
Citations
1
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pressurized liquid extraction and GC/MS determination of model contaminants in HDPE - Application to recycling of post-consumer polyolefins using limonene

Marı́a Teresa Tena, Julia Martı́n, Jorge García-Barrasa
1 citations
Journal of Chromatography A
Microplastics and Plastic Pollution
0.50
article

Pressurized liquid extraction and GC/MS determination of model contaminants in HDPE - Application to recycling of post-consumer polyolefins using limonene

Marı́a Teresa Tena, Julia Martı́n, Jorge García-Barrasa
article en
1 citations

Abstract

A pressurized liquid extraction and gas chromatography-mass spectrometry (PLE-GC/MS) method is developed for the quantification of seven model contaminants in post-consumer and recycled high-density polyethylene (HDPE). Chloroform, toluene, chlorobenzene, methyl salicylate, phenyl cyclohexane, benzophenone, and methyl stearate were selected as model contaminants according to the European Food Safety Authority (EFSA) and the Food and Drug Administration (FDA) recommendations. The GC/MS method presented limits of detection (LOD) under 0.5 µg L<sup>-1</sup> for all contaminants except toluene and methyl stearate (18 µg L<sup>-1</sup> and 310 µg L<sup>-1</sup> respectively). Repeatability and intermediate precision were studied at two concentration levels, with the former presenting relative standard deviations under 10 % and the latter under 17 % in almost all cases. The PLE method was optimized by means of a central composite design (CCD), studying the extraction temperature and time. The selected conditions were three extraction cycles with acetone at 100 °C for 6 min at 1500 psi. Accuracy, repeatability and intermediate precision were stablished for the whole PLE-GC/MS method. Accuracy values were close to 100 % for most of them. Repeatability and intermediate precision were good for most of the model contaminants, with RSD values less than 11 and 17 %, respectively. The PLE-GC/MS method was applied to evaluate, via a challenge test, a novel HDPE recycling method based on the dissolution and precipitation of the polymer using limonene. The recycling method was shown to have high cleaning efficiencies, proving its potential in recycling of HDPE, as well as the utility of the PLE-GC/MS method to carry out challenge test evaluations.

Journal of Chromatography AVol. 1745
Universidad de La Rioja (ES), Universidad Internacional De La Rioja (ES), Gobierno de La Rioja (ES)
Universidad de La Rioja
Openalex Percentile: Top 43%
Microplastics and Plastic Pollution
0.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.