Hydrazine imprinted electrochemical sensor based on cobalt-barium stannate nanoparticles incorporated-functionalized MWCNTs nanocomposite for hydrazine determination in tap water samples

A hydrazine (HYD) detection method is presented based on molecularly imprinting polymers (MIPs) and cobalt-barium stannate nanoparticles incorporated-functionalized MWCNTs (CBSNPs/f-MWCNTs) nanocomposite. Firstly, co-precipitation and sonication techniques were applied to the preparations of CBSNPs and CBSNPs/f-MWCNTs nanocomposite, respectively. Since waste generation occurs at a minimum level in these techniques, an environmentally friendly nanocomposite was prepared. After the glassy carbon electrode modification with CBSNPs and CBSNPs/f-MWCNTs nanocomposite, HYD imprinted electrodes were fabricated using cyclic voltammetry (CV) with a dispersion containing 100.0 mM pyrrole (Py) monomer and 25.0 mM HYD molecule. The resulting electrochemical sensor demonstrated a detection span of 1.0 × 10<sup>-9</sup> M to 1.0 × 10<sup>-8</sup> M HYD and achieved a detection limit (LOD) of 3.0 × 10<sup>-10</sup> M. Furthermore, the developed electrochemical sensor was used for actual tap water samples, and the obtained values close to 100.00% in recovery experiments showed the high accuracy of the developed sensor in real sample analysis. Finally, the selectivity, stability, and reproducibility of the created electrochemical sensor were investigated, and the developed sensor has been demonstrated to have high stability for at least 7 weeks, high reproducibility with a relative standard deviation (RSD) value of 0.14%, and high selectivity in real samples.

Authors

Institutions

Publication Details

Journal
Microchimica Acta
Published
2025-02-01
DOI
https://doi.org/10.1007/s00604-025-06982-9
Citations
32
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
23.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrazine imprinted electrochemical sensor based on cobalt-barium stannate nanoparticles incorporated-functionalized MWCNTs nanocomposite for hydrazine determination in tap water samples

Fatma Hazan Gül, Onur Akyıldırım, Ayla Deveci, Hacı Ahmet Deveci et al.
32 citations
Microchimica Acta
Electrochemical sensors and biosensors
23.37
article

Hydrazine imprinted electrochemical sensor based on cobalt-barium stannate nanoparticles incorporated-functionalized MWCNTs nanocomposite for hydrazine determination in tap water samples

Fatma Hazan Gül, Onur Akyıldırım, Ayla Deveci, Hacı Ahmet Deveci, Mehmet Lütfi Yola
article en
32 citations

Abstract

A hydrazine (HYD) detection method is presented based on molecularly imprinting polymers (MIPs) and cobalt-barium stannate nanoparticles incorporated-functionalized MWCNTs (CBSNPs/f-MWCNTs) nanocomposite. Firstly, co-precipitation and sonication techniques were applied to the preparations of CBSNPs and CBSNPs/f-MWCNTs nanocomposite, respectively. Since waste generation occurs at a minimum level in these techniques, an environmentally friendly nanocomposite was prepared. After the glassy carbon electrode modification with CBSNPs and CBSNPs/f-MWCNTs nanocomposite, HYD imprinted electrodes were fabricated using cyclic voltammetry (CV) with a dispersion containing 100.0 mM pyrrole (Py) monomer and 25.0 mM HYD molecule. The resulting electrochemical sensor demonstrated a detection span of 1.0 × 10<sup>-9</sup> M to 1.0 × 10<sup>-8</sup> M HYD and achieved a detection limit (LOD) of 3.0 × 10<sup>-10</sup> M. Furthermore, the developed electrochemical sensor was used for actual tap water samples, and the obtained values close to 100.00% in recovery experiments showed the high accuracy of the developed sensor in real sample analysis. Finally, the selectivity, stability, and reproducibility of the created electrochemical sensor were investigated, and the developed sensor has been demonstrated to have high stability for at least 7 weeks, high reproducibility with a relative standard deviation (RSD) value of 0.14%, and high selectivity in real samples.

Microchimica ActaVol. 192(2)
Kafkas University (TR), Kilis 7 Aralık University (TR), Hasan Kalyoncu University (TR), Mersin Üniversitesi (TR), Gaziantep University (TR)
Openalex Percentile: Top 0%
Electrochemical sensors and biosensors
23.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.