Study on the optimal structure of nonmetallic coiled tubing with cable-laying based on the minimum stress in optical fibers

• The study designed three distinct tubing structures of nonmetallic coiled tubing with cable-laying. The cables demonstrate a variable stress distribution throughout all three structures, featuring areas of both elevated and reduced stress. • The positioning of the cables significantly affects the stress experienced by each integrated layer of the pipeline under the internal pressure. Conversely, this positioning exerts minimal influence on the stress distribution within the cables themself. • The optical fiber embedded reinforcement layer structure was considered as the optimal structure of the nonmetallic coiled tubing with a cable-laying, which minimizes the stress experienced by the optical fibers under load, thereby enhancing the operational lifespan of the tubing while maintaining its effective load-bearing capacity. • Field evaluations of the tubing featuring an optimal structure have revealed that the internal optical fiber exhibits effective monitoring capabilities. This study designs of three distinct nonmetallic coiled tubing structures, each featuring different configurations for the arrangement of optical fibers. The mechanical behavior of the cable integration layer, along with the optical fibers, is examined under internal pressure through finite element simulation analysis. The ideal configuration of the nonmetallic coiled tubing structure is determined with the objective of reducing the stress imposed on the optical fibers. The results indicate that the positioning of the cables significantly affects the stress experienced by each integrated layer of the pipeline. Conversely, this positioning exerts minimal influence on the stress distribution within the cables themself. The cables exhibit a distribution of alternating stress, characterized by regions of both high and low stress, across the three structures. The stress experienced by optical fibers under internal pressure is affected by their spatial arrangement and the compressive stress present in the fiber integration layer. The integration of optical fibers into the reinforcement layer leads to a reduction in stress on the fibers. In comparison to other configurations, this methodology yields a reduction in maximum stresses on temperature and vibration sensing optical fibers by approximately 9.4 % and 14.3 %, respectively. Furthermore, the maximum stresses on strain sensing optical fibers are diminished by 27.1 % and 17.0 %. Consequently, the design incorporating embedded optical fibers within the reinforcement layer represents the most optimal structure for cable installation. Utilizing this optimal structure, the corresponding nonmetallic coiled tubing with cable-laying is manufactured. Field tests indicate that the internal optical fiber has good monitoring ability.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-02-01
DOI
https://doi.org/10.1016/j.rineng.2025.104226
Citations
1
Primary Topic
Advanced Surface Polishing Techniques
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the optimal structure of nonmetallic coiled tubing with cable-laying based on the minimum stress in optical fibers

Houbu Li, Nan Ding, Lei Li, Xuemin Zhang et al.
1 citations
Results in Engineering
Advanced Surface Polishing Techniques
0.67
article

Study on the optimal structure of nonmetallic coiled tubing with cable-laying based on the minimum stress in optical fibers

Houbu Li, Nan Ding, Lei Li, Xuemin Zhang, Xueru Zhang
article en
1 citations

Abstract

• The study designed three distinct tubing structures of nonmetallic coiled tubing with cable-laying. The cables demonstrate a variable stress distribution throughout all three structures, featuring areas of both elevated and reduced stress. • The positioning of the cables significantly affects the stress experienced by each integrated layer of the pipeline under the internal pressure. Conversely, this positioning exerts minimal influence on the stress distribution within the cables themself. • The optical fiber embedded reinforcement layer structure was considered as the optimal structure of the nonmetallic coiled tubing with a cable-laying, which minimizes the stress experienced by the optical fibers under load, thereby enhancing the operational lifespan of the tubing while maintaining its effective load-bearing capacity. • Field evaluations of the tubing featuring an optimal structure have revealed that the internal optical fiber exhibits effective monitoring capabilities. This study designs of three distinct nonmetallic coiled tubing structures, each featuring different configurations for the arrangement of optical fibers. The mechanical behavior of the cable integration layer, along with the optical fibers, is examined under internal pressure through finite element simulation analysis. The ideal configuration of the nonmetallic coiled tubing structure is determined with the objective of reducing the stress imposed on the optical fibers. The results indicate that the positioning of the cables significantly affects the stress experienced by each integrated layer of the pipeline. Conversely, this positioning exerts minimal influence on the stress distribution within the cables themself. The cables exhibit a distribution of alternating stress, characterized by regions of both high and low stress, across the three structures. The stress experienced by optical fibers under internal pressure is affected by their spatial arrangement and the compressive stress present in the fiber integration layer. The integration of optical fibers into the reinforcement layer leads to a reduction in stress on the fibers. In comparison to other configurations, this methodology yields a reduction in maximum stresses on temperature and vibration sensing optical fibers by approximately 9.4 % and 14.3 %, respectively. Furthermore, the maximum stresses on strain sensing optical fibers are diminished by 27.1 % and 17.0 %. Consequently, the design incorporating embedded optical fibers within the reinforcement layer represents the most optimal structure for cable installation. Utilizing this optimal structure, the corresponding nonmetallic coiled tubing with cable-laying is manufactured. Field tests indicate that the internal optical fiber has good monitoring ability.

Results in EngineeringVol. 25
Chang'an University (CN), China National Petroleum Corporation (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 35%
Advanced Surface Polishing Techniques
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.