Effects of defect locations and loading voltages on breakdown of GIL tri-post insulators

The gas insulated transmission lines (GIL) are critical components of power transmission systems, where insulators provide both electrical insulation and mechanical support. However, breakdown failures of insulators frequently occur, posing a threat to the safety of power systems. The highlights of this paper are as follows: • Systematic studies were conducted on the breakdown processes and underlying mechanisms of GIL insulators. • A numerical model was proposed to simulate the breakdown process of the GIL insulator. • Experimental and simulation results successfully replicate a real-world GIL failure case. The tri-post insulator is a critical component in Gas Insulated Transmission Lines (GIL). However, breakdown incidents involving tri-post insulators are frequent, posing risks to the safety and reliability of GIL systems. This paper investigates the effects of defect locations and loading voltages on the progression of damage channels in tri-post insulators through both experimental and simulation methods. Results show that the development of damage channels in insulators is influenced by electric field lines. Specifically, when the defect is located on the ground (GND) side of the insulator, the damage channel converges toward the center axis of the post. Conversely, when the defect is on the high-voltage (HV) side in the belly, the damage channel is divided into three segments: “internal-surface-internal.” The progression speed of the damage channel is influenced by the electric field strength at its front end, leading to shorter breakdown time and more side branches as the channel develops. When the defect is on the HV side, the breakdown duration is longer than when it is on the GND side. Additionally, loading voltage also affects the development of damage channels, resulting in varying breakdown morphologies within insulators. The findings of this study provide valuable insights for identifying the origins of breakdown faults and optimizing the design of GIL insulators.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-02-01
DOI
https://doi.org/10.1016/j.rineng.2025.104227
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of defect locations and loading voltages on breakdown of GIL tri-post insulators

Jianan Dong, Hucheng Liang, Yun Chen, Zehua Wang et al.
1 citations
Results in Engineering
High voltage insulation and dielectric phenomena
0.52
article

Effects of defect locations and loading voltages on breakdown of GIL tri-post insulators

Jianan Dong, Hucheng Liang, Yun Chen, Zehua Wang, Boxue X. Du, Zhijun Guo
article en
1 citations

Abstract

The gas insulated transmission lines (GIL) are critical components of power transmission systems, where insulators provide both electrical insulation and mechanical support. However, breakdown failures of insulators frequently occur, posing a threat to the safety of power systems. The highlights of this paper are as follows: • Systematic studies were conducted on the breakdown processes and underlying mechanisms of GIL insulators. • A numerical model was proposed to simulate the breakdown process of the GIL insulator. • Experimental and simulation results successfully replicate a real-world GIL failure case. The tri-post insulator is a critical component in Gas Insulated Transmission Lines (GIL). However, breakdown incidents involving tri-post insulators are frequent, posing risks to the safety and reliability of GIL systems. This paper investigates the effects of defect locations and loading voltages on the progression of damage channels in tri-post insulators through both experimental and simulation methods. Results show that the development of damage channels in insulators is influenced by electric field lines. Specifically, when the defect is located on the ground (GND) side of the insulator, the damage channel converges toward the center axis of the post. Conversely, when the defect is on the high-voltage (HV) side in the belly, the damage channel is divided into three segments: “internal-surface-internal.” The progression speed of the damage channel is influenced by the electric field strength at its front end, leading to shorter breakdown time and more side branches as the channel develops. When the defect is on the HV side, the breakdown duration is longer than when it is on the GND side. Additionally, loading voltage also affects the development of damage channels, resulting in varying breakdown morphologies within insulators. The findings of this study provide valuable insights for identifying the origins of breakdown faults and optimizing the design of GIL insulators.

Results in EngineeringVol. 25
North China Electric Power University (CN), Tianjin University (CN), Tianjin Research Institute of Electric Science (China) (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 42%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.