Field Studies of Technologies for Reducing Frost Heaving of Line Supports in the Conditions of the Republic of Sakha (Yakutia)

Frost heaving of power transmission line supports in regions with permafrost soils directly affects the reliability and uninterruptible operation of power supply systems. The article provides information on the work on field studies of the effectiveness of using anti-heaving coatings and shells "Reline" in application to wooden and concrete foundations of overhead power transmission line supports to reduce the tangential forces of frost heaving of soils in the climatic and geocryological conditions of the Republic of Sakha (Yakutia). During the work, a test site was set up on a heaving site in the city of Yakutsk, 12 cycles of monitoring the altitude position of the support foundations and the temperature regime of the soil were carried out. The obtained results demonstrate the efficiency of using the tested coatings in the conditions of the Republic of Sakha (Yakutia).The work was carried out by Yakutsk Design Research Institute of Construction and Ural Plant of Polymer Technologies "Mayak" by order of PJSC "Yakutskenergo".

Authors

Institutions

Publication Details

Journal
Energy Systems Research
Published
2024-12-28
DOI
https://doi.org/10.25729/esr.2024.04.0013
Primary Topic
Advanced Energy Technologies and Civil Engineering Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field Studies of Technologies for Reducing Frost Heaving of Line Supports in the Conditions of the Republic of Sakha (Yakutia)

Vladimir M. Efimov, V.A. Belyakov, K. Bolvshev, A.S. Unzhakov
Energy Systems Research
Advanced Energy Technologies and Civil Engineering Innovations
article

Field Studies of Technologies for Reducing Frost Heaving of Line Supports in the Conditions of the Republic of Sakha (Yakutia)

Vladimir M. Efimov, V.A. Belyakov, K. Bolvshev, A.S. Unzhakov
article en

Abstract

Frost heaving of power transmission line supports in regions with permafrost soils directly affects the reliability and uninterruptible operation of power supply systems. The article provides information on the work on field studies of the effectiveness of using anti-heaving coatings and shells "Reline" in application to wooden and concrete foundations of overhead power transmission line supports to reduce the tangential forces of frost heaving of soils in the climatic and geocryological conditions of the Republic of Sakha (Yakutia). During the work, a test site was set up on a heaving site in the city of Yakutsk, 12 cycles of monitoring the altitude position of the support foundations and the temperature regime of the soil were carried out. The obtained results demonstrate the efficiency of using the tested coatings in the conditions of the Republic of Sakha (Yakutia).The work was carried out by Yakutsk Design Research Institute of Construction and Ural Plant of Polymer Technologies "Mayak" by order of PJSC "Yakutskenergo".

Energy Systems ResearchVol. 7(4(28))
Institute of Physico-Technical Problems of the North named VP Larionov (RU), Yakut Scientific Research Institute of Agriculture (RU)
Openalex Percentile: Top 61%
Advanced Energy Technologies and Civil Engineering Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Field Studies of Technologies for Reducing Frost Heaving of Line Supports in the Conditions of the Republic of Sakha (Yakutia) — Vladimir M. Efimov, V.A. Belyakov, et al. · Energy Systems Research (2024) | TGRS Research Map | TGRS