An Improved Harmonic Detection Method for Active Power Filter

With the development of power systems, the harmonic problem has become more and more prominent. In the application of active power filters, the traditional ip-iq algorithm can only detect total harmonics and cannot obtain specific harmonics. To address this problem, this paper proposes an improved ip-iq algorithm for active power filters. This algorithm is improved based on the difference in separation objects of harmonic detection algorithms. It can convert specific harmonics into DC components. After low-pass filtering and inverse transformation, the specific harmonic components in the original three-phase current can be obtained. Compared with the traditional algorithm, mainly by modifying the transformation matrix <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$C_{x}$</tex> and its inverse matrix <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">${C_{x}}^{-1}$</tex> according to the difference between positive and negative sequence harmonics, it is simple to implement in active power filters and does not require complex calculations, greatly expanding the harmonic detection range and accurately detecting specified harmonics. A simulation model is constructed using Matlab/Simulink software to detect the 5th and 7th harmonics under two conditions of different harmonic contents in grid current. The results show that in the application of active power filters, when the content of specified harmonics is large, the detection result is more accurate. When the content is small, although there may be errors due to interference from other harmonics, it is within an acceptable range. Thus, the feasibility and effectiveness of the improved ip-iq algorithm in detecting specific harmonics in active power filters are verified.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/icpes63746.2024.10856534
Citations
2
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Improved Harmonic Detection Method for Active Power Filter

Jiaxin Xu, Dayi Li, Tiantian Cao, Xinchun Wan et al.
2 citations
Power Quality and Harmonics
0.42
article

An Improved Harmonic Detection Method for Active Power Filter

Jiaxin Xu, Dayi Li, Tiantian Cao, Xinchun Wan, Zhengyang Ye, Yufeng Dai
article en
2 citations

Abstract

With the development of power systems, the harmonic problem has become more and more prominent. In the application of active power filters, the traditional ip-iq algorithm can only detect total harmonics and cannot obtain specific harmonics. To address this problem, this paper proposes an improved ip-iq algorithm for active power filters. This algorithm is improved based on the difference in separation objects of harmonic detection algorithms. It can convert specific harmonics into DC components. After low-pass filtering and inverse transformation, the specific harmonic components in the original three-phase current can be obtained. Compared with the traditional algorithm, mainly by modifying the transformation matrix <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$C_{x}$</tex> and its inverse matrix <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">${C_{x}}^{-1}$</tex> according to the difference between positive and negative sequence harmonics, it is simple to implement in active power filters and does not require complex calculations, greatly expanding the harmonic detection range and accurately detecting specified harmonics. A simulation model is constructed using Matlab/Simulink software to detect the 5th and 7th harmonics under two conditions of different harmonic contents in grid current. The results show that in the application of active power filters, when the content of specified harmonics is large, the detection result is more accurate. When the content is small, although there may be errors due to interference from other harmonics, it is within an acceptable range. Thus, the feasibility and effectiveness of the improved ip-iq algorithm in detecting specific harmonics in active power filters are verified.

Huazhong University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 35%
Power Quality and Harmonics
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.