Disipadores de fluido viscoso en el comportamiento estructural de un hotel de ocho niveles

Seismic events cause damage and collapse of buildings, resulting in human, material, and economic losses. To improve seismic performance and reduce damage to buildings, viscous fluid dampers are used. The objective of this study was to determine the influence of viscous fluid dampers on the structural behavior of an eight-story hotel in the city of Cajamarca. For this purpose, a geotechnical study was conducted. The static and dynamic seismic analysis of the structure indicates that the maximum displacements and drifts comply with the E.030 code; however, when performing the time-history analysis, the maximum drifts exceeded the permitted limits (0.007). The incorporation of viscous fluid dampers met the target drift (0.0042) of HAZUS for a functional performance level, reducing the drifts in X and Y directions by up to 55% and 65%, respectively. Additionally, the dampers dissipated 70.56% of the seismic energy, with the structure dissipating 29.44%. It is concluded that the integrated dissipation system significantly influences structural behavior, reducing displacements, drifts, and dissipated energy.

Authors

Publication Details

Journal
REVISTA NOR NDINA
Published
2024-12-31
DOI
https://doi.org/10.37518/2663-6360x2024v7n2p286
Primary Topic
Historical and socio-economic studies of Spain and related regions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Disipadores de fluido viscoso en el comportamiento estructural de un hotel de ocho niveles

Dany Vargas Valdivia
REVISTA NOR NDINA
Historical and socio-economic studies of Spain and related regions
article

Disipadores de fluido viscoso en el comportamiento estructural de un hotel de ocho niveles

Dany Vargas Valdivia
article en

Abstract

Seismic events cause damage and collapse of buildings, resulting in human, material, and economic losses. To improve seismic performance and reduce damage to buildings, viscous fluid dampers are used. The objective of this study was to determine the influence of viscous fluid dampers on the structural behavior of an eight-story hotel in the city of Cajamarca. For this purpose, a geotechnical study was conducted. The static and dynamic seismic analysis of the structure indicates that the maximum displacements and drifts comply with the E.030 code; however, when performing the time-history analysis, the maximum drifts exceeded the permitted limits (0.007). The incorporation of viscous fluid dampers met the target drift (0.0042) of HAZUS for a functional performance level, reducing the drifts in X and Y directions by up to 55% and 65%, respectively. Additionally, the dampers dissipated 70.56% of the seismic energy, with the structure dissipating 29.44%. It is concluded that the integrated dissipation system significantly influences structural behavior, reducing displacements, drifts, and dissipated energy.

REVISTA NOR NDINAVol. 7(2)
Sustainable cities and communities
Openalex Percentile: Top 68%
Historical and socio-economic studies of Spain and related regions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Disipadores de fluido viscoso en el comportamiento estructural de un hotel de ocho niveles — Dany Vargas Valdivia · REVISTA NOR NDINA (2024) | TGRS Research Map | TGRS