Radiologist-in-the-Loop Self-Training for Generalizable CT Metal Artifact Reduction

Metal artifacts in computed tomography (CT) images can significantly degrade image quality and impede accurate diagnosis. Supervised metal artifact reduction (MAR) methods, trained using simulated datasets, often struggle to perform well on real clinical CT images due to a substantial domain gap. Although state-of-the-art semi-supervised methods use pseudo ground-truths generated by a prior network to mitigate this issue, their reliance on a fixed prior limits both the quality and quantity of these pseudo ground-truths, introducing confirmation bias and reducing clinical applicability. To address these limitations, we propose a novel radiologist-in-the-loop self-training framework for MAR, termed RISE-MAR, which can integrate radiologists' feedback into the semi-supervised learning process, progressively improving the quality and quantity of pseudo ground-truths for enhanced generalization on real clinical CT images. For quality assurance, we introduce a clinical quality assessor model that emulates radiologist evaluations, effectively selecting high-quality pseudo ground-truths for semi-supervised training. For quantity assurance, our self-training framework iteratively generates additional high-quality pseudo ground-truths, expanding the clinical dataset and further improving model generalization. Extensive experimental results on multiple clinical datasets demonstrate the superior generalization performance of our RISE-MAR over state-of-the-art methods, advancing the development of MAR models for practical application. The source code is available at https://github.com/Masaaki-75/rise-mar.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2025-01-29
DOI
https://doi.org/10.1109/tmi.2025.3535906
Citations
3
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiologist-in-the-Loop Self-Training for Generalizable CT Metal Artifact Reduction

Jiannan Liu, Yuanlin Li, Hongming Shan, Yi Zhang et al.
3 citations
IEEE Transactions on Medical Imaging
Advanced X-ray and CT Imaging
2.02
article

Radiologist-in-the-Loop Self-Training for Generalizable CT Metal Artifact Reduction

Jiannan Liu, Yuanlin Li, Hongming Shan, Yi Zhang, Junping Zhang, Chenglong Ma, Jing Han, Zilong Li
article en
3 citations

Abstract

Metal artifacts in computed tomography (CT) images can significantly degrade image quality and impede accurate diagnosis. Supervised metal artifact reduction (MAR) methods, trained using simulated datasets, often struggle to perform well on real clinical CT images due to a substantial domain gap. Although state-of-the-art semi-supervised methods use pseudo ground-truths generated by a prior network to mitigate this issue, their reliance on a fixed prior limits both the quality and quantity of these pseudo ground-truths, introducing confirmation bias and reducing clinical applicability. To address these limitations, we propose a novel radiologist-in-the-loop self-training framework for MAR, termed RISE-MAR, which can integrate radiologists' feedback into the semi-supervised learning process, progressively improving the quality and quantity of pseudo ground-truths for enhanced generalization on real clinical CT images. For quality assurance, we introduce a clinical quality assessor model that emulates radiologist evaluations, effectively selecting high-quality pseudo ground-truths for semi-supervised training. For quantity assurance, our self-training framework iteratively generates additional high-quality pseudo ground-truths, expanding the clinical dataset and further improving model generalization. Extensive experimental results on multiple clinical datasets demonstrate the superior generalization performance of our RISE-MAR over state-of-the-art methods, advancing the development of MAR models for practical application. The source code is available at https://github.com/Masaaki-75/rise-mar.

IEEE Transactions on Medical ImagingVol. 44(6)
Sichuan University (CN), Fudan University (CN), Shanghai Ninth People's Hospital (CN), Shanghai Center for Brain Science and Brain-Inspired Technology (CN)
Shanghai Center for Brain Science and Brain-Inspired Technology, National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Climate action
Openalex Percentile: Top 16%
Advanced X-ray and CT Imaging
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.