Sustainable electrochemical sensors from cork-derived laser induced graphene: Non-enzymatic glucose detection in urine

Laser Induced Graphene (LIG) is a highly versatile material with exceptional electrical conductivity and large surface area obtained through the laser pyrolysis of aromatic plastics like polyimides. The recent remarkable discovery that LIG can also be synthesized from environmentally friendly materials like cork, extends application to the manufacture of sustainable, biocompatible, and eco-friendly devices such as biosensors. Here we present the fabrication of a novel “green” non-enzymatic glucose sensor obtained by direct laser writing of flexible cork sheets. To enable glucose detection, the cork sheets were wetted with an aqueous CuSO 4 solution. Laser graphitization promoted the conversion of CuSO 4 into CuO nanoparticles and resulted in formation of copper-cork Laser Induced Graphene (Cu-cLIG) materials displaying high surface area and high density of CuO NPs embedded in the cLIG matrix. The sensor showed excellent glucose sensing performance in buffer and good selectivity over interfering molecules. A fully laser written sensor was also fabricated and tested for detection of glucose in artificial urine. The sensor exhibited high stability and reproducibility, allowing glucose detection in artificial urine with a high sensitivity of 223 μ A / mM ⋅ c m 2 and a LOD of 9.7 μ M . This easy and eco-friendly fabrication method, combined with the use of renewable and abundant precursor materials, paves the way for the development of truly sustainable sensing platforms for future green electronics. • Cu-decorated Laser Induced Graphene from natural cork was successfully obtained. • Non-enzymatic glucose sustainable sensors were manufactured in one-step laser process. • “Green” Cu-cork graphene sensors exhibited high selectivity and sensitivity in artificial urine.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-01-29
DOI
https://doi.org/10.1016/j.snb.2025.137352
Citations
29
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
21.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sustainable electrochemical sensors from cork-derived laser induced graphene: Non-enzymatic glucose detection in urine

Daniele Pontiroli, Richard Murray, Labrini Sygellou, Michele Setti et al.
29 citations
Sensors and Actuators B Chemical
Electrochemical sensors and biosensors
21.18
article

Sustainable electrochemical sensors from cork-derived laser induced graphene: Non-enzymatic glucose detection in urine

Daniele Pontiroli, Richard Murray, Labrini Sygellou, Michele Setti, Daniela Iacopino, Mauro Riccò, Aidan J. Quinn, Eoghan Vaughan
article en
29 citations

Abstract

Laser Induced Graphene (LIG) is a highly versatile material with exceptional electrical conductivity and large surface area obtained through the laser pyrolysis of aromatic plastics like polyimides. The recent remarkable discovery that LIG can also be synthesized from environmentally friendly materials like cork, extends application to the manufacture of sustainable, biocompatible, and eco-friendly devices such as biosensors. Here we present the fabrication of a novel “green” non-enzymatic glucose sensor obtained by direct laser writing of flexible cork sheets. To enable glucose detection, the cork sheets were wetted with an aqueous CuSO 4 solution. Laser graphitization promoted the conversion of CuSO 4 into CuO nanoparticles and resulted in formation of copper-cork Laser Induced Graphene (Cu-cLIG) materials displaying high surface area and high density of CuO NPs embedded in the cLIG matrix. The sensor showed excellent glucose sensing performance in buffer and good selectivity over interfering molecules. A fully laser written sensor was also fabricated and tested for detection of glucose in artificial urine. The sensor exhibited high stability and reproducibility, allowing glucose detection in artificial urine with a high sensitivity of 223 μ A / mM ⋅ c m 2 and a LOD of 9.7 μ M . This easy and eco-friendly fabrication method, combined with the use of renewable and abundant precursor materials, paves the way for the development of truly sustainable sensing platforms for future green electronics. • Cu-decorated Laser Induced Graphene from natural cork was successfully obtained. • Non-enzymatic glucose sustainable sensors were manufactured in one-step laser process. • “Green” Cu-cork graphene sensors exhibited high selectivity and sensitivity in artificial urine.

Sensors and Actuators B ChemicalVol. 430
University of Parma (IT), University College Cork (IE), National Interuniversity Consortium of Materials Science and Technology (IT), Foundation for Research and Technology Hellas (GR)
European Commission
Responsible consumption and production
Openalex Percentile: Top 0%
Electrochemical sensors and biosensors
21.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.