A Test-Retest Study of Single- and Multi-Delay pCASL for Choroid Plexus Perfusion Imaging in Healthy Subjects Aged 19 to 87 Years

There is a growing interest in the choroid plexus (ChP) due to its critical role in cerebrospinal fluid (CSF) production and its involvement in neurodegenerative and cerebrovascular diseases. However, comprehensive studies comparing the accuracy and reliability of single- and multi-PLD (post-labeling delay) arterial spin labeling (ASL) techniques, specifically in relation to the ChP, remain limited. This study systematically evaluated the test-retest reliability and quantification accuracy of cerebral blood flow (CBF) measurements, focusing on the ChP, using single-delay and multi-delay 3D gradient-and-spin echo (GRASE) pseudo-continuous ASL (pCASL) on 28 subjects (aged 19 to 87 years, 14 males/14 females) at 3.0 tesla. Both single-delay (2 s) and 5-PLD (0.5 - 2.5 s) pCASL scans were repeated approximately one week apart with a spatial resolution of 2.5 × 2.5 × 3 mm³. Voxel-wise and regional CBF and arterial transit time (ATT) measurements were compared to assess test-retest reliability, with a particular focus on ChP perfusion changes with age. In this study, 12.15 % of ChP voxels exhibited ATTs longer than 2 s, potentially leading to a significant underestimation of CBF using single-delay ASL. Multi-delay ASL showed improved accuracy in estimating CBF values for the ChP compared to single-delay ASL when ATT > PLD. Additionally, ChP volume (mean ± std = 1.72± 0.85 ml) increased (p < 0.01) and ChP perfusion (43.07±14.18 mL/100 g/min) decreased (p = 0.04) with age. These findings underscore the robustness of multi-delay ASL with model-fitting quantification in assessing ChP perfusion, making it the preferred method for accurate CBF and ATT estimation, particularly in regions with prolonged transit time such as ChP.

Authors

Institutions

Publication Details

Journal
NeuroImage
Published
2025-01-29
DOI
https://doi.org/10.1016/j.neuroimage.2025.121048
Citations
6
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
8.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Test-Retest Study of Single- and Multi-Delay pCASL for Choroid Plexus Perfusion Imaging in Healthy Subjects Aged 19 to 87 Years

Xingfeng Shao, Qinyang Shou, Kay Jann, Chenyang Zhao et al.
6 citations
NeuroImage
Advanced MRI Techniques and Applications
8.16
article

A Test-Retest Study of Single- and Multi-Delay pCASL for Choroid Plexus Perfusion Imaging in Healthy Subjects Aged 19 to 87 Years

Xingfeng Shao, Qinyang Shou, Kay Jann, Chenyang Zhao, Danny J.J. Wang, Zixuan Liu
article en
6 citations

Abstract

There is a growing interest in the choroid plexus (ChP) due to its critical role in cerebrospinal fluid (CSF) production and its involvement in neurodegenerative and cerebrovascular diseases. However, comprehensive studies comparing the accuracy and reliability of single- and multi-PLD (post-labeling delay) arterial spin labeling (ASL) techniques, specifically in relation to the ChP, remain limited. This study systematically evaluated the test-retest reliability and quantification accuracy of cerebral blood flow (CBF) measurements, focusing on the ChP, using single-delay and multi-delay 3D gradient-and-spin echo (GRASE) pseudo-continuous ASL (pCASL) on 28 subjects (aged 19 to 87 years, 14 males/14 females) at 3.0 tesla. Both single-delay (2 s) and 5-PLD (0.5 - 2.5 s) pCASL scans were repeated approximately one week apart with a spatial resolution of 2.5 × 2.5 × 3 mm³. Voxel-wise and regional CBF and arterial transit time (ATT) measurements were compared to assess test-retest reliability, with a particular focus on ChP perfusion changes with age. In this study, 12.15 % of ChP voxels exhibited ATTs longer than 2 s, potentially leading to a significant underestimation of CBF using single-delay ASL. Multi-delay ASL showed improved accuracy in estimating CBF values for the ChP compared to single-delay ASL when ATT > PLD. Additionally, ChP volume (mean ± std = 1.72± 0.85 ml) increased (p < 0.01) and ChP perfusion (43.07±14.18 mL/100 g/min) decreased (p = 0.04) with age. These findings underscore the robustness of multi-delay ASL with model-fitting quantification in assessing ChP perfusion, making it the preferred method for accurate CBF and ATT estimation, particularly in regions with prolonged transit time such as ChP.

NeuroImageVol. 308
University of Southern California (US)
National Institutes of Health
Zero hunger
Openalex Percentile: Top 3%
Advanced MRI Techniques and Applications
8.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.