P-1253. Validating and Comparing the Predictiveness of Cefepime Pharmacokinetic Models Used in Bayesian Dosing

Abstract Background Bayesian software may enhance beta-lactam dosing. Therefore, we analyzed the predictiveness of cefepime pharmacokinetic (PK) models for use as Bayesian priors. Methods Data on adult patients receiving cefepime intravenous therapy were entered into a Bayesian software at 2 sites. Inclusion criteria encompassed patients with ≥ 1 cefepime drug concentration (TDM), including those undergoing continuous renal replacement therapy. Exclusion criteria were dialysis and outlier TDMs defined as > 3 standard deviations above the mean. Adult parametric PK models were identified and implemented using PKPDsim. Measured TDMs were predicted iteratively, using model priors to predict the first set (“a priori”), with subsequent TDMs predicted using Bayesian estimation (“a posteriori”), to mirror the clinical experience (i.e., initial predictions were made using only demographics; updated predictions were made using each additional TDM event). TDMs were analyzed separately as peaks or as random/trough levels. Mean percent error (MPE) assessed bias and root mean square error (RMSE) assessed imprecision. Statistical significance was determined using overlapping 90% confidence intervals from 1000 bootstrap simulations. Results A total of 114 patients with 200 TDMs for a priori and 35 TDMs for a posteriori predictions were included (Table 1). Five PK models were identified (Table 2). The An et al. and Jonckheere et al. models were most predictive, with acceptable RMSE ≤ 25 mg/L and bias < 25% (Fig 1.). The An et al. model was most precise a priori (RMSEpeak: 23 mg/L, RMSErandom/trough: 19 mg/L versus other models ranging from 26-33 mg/L and 23-30 mg/L) but demonstrated bias in predicting peaks a priori (MPE: 24%) that was not improved a posteriori. The Jonckheere et al. model demonstrated similar precision a priori to the An et al. model and showed better precision in predicting peaks a posteriori (RMSEpeak: 6 mg/L versus other models ranging from 13-25 mg/ L; Fig 1.). Conclusion While many models performed similarly (overlapping 90% CI), the An and Jonckheere models both demonstrated acceptable bias and precision for predicting random/trough levels. Centers using a random/trough sampling approach to estimate cefepime exposures may find these models clinically useful. Disclosures Maria-Stephanie Hughes, PharmD, InsightRX: Employee of company|InsightRX: Stocks/Bonds (Private Company) Nathaniel J. Rhodes, PharmD MS, Apothecademy, LLC: Advisor/Consultant Brandon Smith, MD, PharmD, Melinta Therapeutics: Advisor/Consultant|Shionogi, INC: Advisor/Consultant Ryan K. Shields, PharmD, MS, Allergan: Advisor/Consultant|Cidara: Advisor/Consultant|Entasis: Advisor/Consultant|GSK: Advisor/Consultant|Melinta: Advisor/Consultant|Melinta: Grant/Research Support|Menarini: Advisor/Consultant|Merck: Advisor/Consultant|Merck: Grant/Research Support|Pfizer: Advisor/Consultant|Roche: Grant/Research Support|Shionogi: Advisor/Consultant|Shionogi: Grant/Research Support|Utility: Advisor/Consultant|Venatorx: Advisor/Consultant|Venatorx: Grant/Research Support Jasmine Hughes, PhD, InsightRX: Employee|InsightRX: Stocks/Bonds (Private Company)

Authors

Institutions

Publication Details

Journal
Open Forum Infectious Diseases
Published
2025-01-29
DOI
https://doi.org/10.1093/ofid/ofae631.1435
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P-1253. Validating and Comparing the Predictiveness of Cefepime Pharmacokinetic Models Used in Bayesian Dosing

Brandon Smith, Samantha Pan, Maria‐Stephanie A. Hughes, Nathaniel J. Rhodes et al.
Open Forum Infectious Diseases
Antibiotics Pharmacokinetics and Efficacy
article

P-1253. Validating and Comparing the Predictiveness of Cefepime Pharmacokinetic Models Used in Bayesian Dosing

Brandon Smith, Samantha Pan, Maria‐Stephanie A. Hughes, Nathaniel J. Rhodes, Shannon Galvin, Erin Weslander, Ryan K. Shields, Jasmine Hughes
article en

Abstract

Abstract Background Bayesian software may enhance beta-lactam dosing. Therefore, we analyzed the predictiveness of cefepime pharmacokinetic (PK) models for use as Bayesian priors. Methods Data on adult patients receiving cefepime intravenous therapy were entered into a Bayesian software at 2 sites. Inclusion criteria encompassed patients with ≥ 1 cefepime drug concentration (TDM), including those undergoing continuous renal replacement therapy. Exclusion criteria were dialysis and outlier TDMs defined as > 3 standard deviations above the mean. Adult parametric PK models were identified and implemented using PKPDsim. Measured TDMs were predicted iteratively, using model priors to predict the first set (“a priori”), with subsequent TDMs predicted using Bayesian estimation (“a posteriori”), to mirror the clinical experience (i.e., initial predictions were made using only demographics; updated predictions were made using each additional TDM event). TDMs were analyzed separately as peaks or as random/trough levels. Mean percent error (MPE) assessed bias and root mean square error (RMSE) assessed imprecision. Statistical significance was determined using overlapping 90% confidence intervals from 1000 bootstrap simulations. Results A total of 114 patients with 200 TDMs for a priori and 35 TDMs for a posteriori predictions were included (Table 1). Five PK models were identified (Table 2). The An et al. and Jonckheere et al. models were most predictive, with acceptable RMSE ≤ 25 mg/L and bias < 25% (Fig 1.). The An et al. model was most precise a priori (RMSEpeak: 23 mg/L, RMSErandom/trough: 19 mg/L versus other models ranging from 26-33 mg/L and 23-30 mg/L) but demonstrated bias in predicting peaks a priori (MPE: 24%) that was not improved a posteriori. The Jonckheere et al. model demonstrated similar precision a priori to the An et al. model and showed better precision in predicting peaks a posteriori (RMSEpeak: 6 mg/L versus other models ranging from 13-25 mg/ L; Fig 1.). Conclusion While many models performed similarly (overlapping 90% CI), the An and Jonckheere models both demonstrated acceptable bias and precision for predicting random/trough levels. Centers using a random/trough sampling approach to estimate cefepime exposures may find these models clinically useful. Disclosures Maria-Stephanie Hughes, PharmD, InsightRX: Employee of company|InsightRX: Stocks/Bonds (Private Company) Nathaniel J. Rhodes, PharmD MS, Apothecademy, LLC: Advisor/Consultant Brandon Smith, MD, PharmD, Melinta Therapeutics: Advisor/Consultant|Shionogi, INC: Advisor/Consultant Ryan K. Shields, PharmD, MS, Allergan: Advisor/Consultant|Cidara: Advisor/Consultant|Entasis: Advisor/Consultant|GSK: Advisor/Consultant|Melinta: Advisor/Consultant|Melinta: Grant/Research Support|Menarini: Advisor/Consultant|Merck: Advisor/Consultant|Merck: Grant/Research Support|Pfizer: Advisor/Consultant|Roche: Grant/Research Support|Shionogi: Advisor/Consultant|Shionogi: Grant/Research Support|Utility: Advisor/Consultant|Venatorx: Advisor/Consultant|Venatorx: Grant/Research Support Jasmine Hughes, PhD, InsightRX: Employee|InsightRX: Stocks/Bonds (Private Company)

Open Forum Infectious DiseasesVol. 12(Supplement_1)
Northwestern University (US), Midwestern University (US), University of Pittsburgh (US), Northwestern Memorial Hospital (US), University of Pittsburgh Medical Center (US)
Openalex Percentile: Top 98%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.