A Modelling of 500 Kv Long Transmission Line and Fault Detection Using Inverse Definite Minimum Time Over Current (IDMT O/C) relay

As electricity demand increases day by day due to economic growth, the process of transmitting efficient electrical power is vital. Thus, a power simulation study is required to determine the mechanism of the transmission line, and possible faults that occurred in the transmission line system. On a daily basis, single line to ground fault (L-G), double line to ground fault (2L-G), and triple line to ground fault (3L-G) are the faults that normally occur in the long transmission line system. In this project, a model of a 300km/500 kV EHV transmission line consisting of a three-phase source, distribution line, and load is simulated using MATLAB software. When the L – G fault is applied, the voltage is diminished to zero and upon fault clearance, the R – G line produced overvoltage and overcurrent by 518.9 kV and 1889 A, which increased about 46.83% and 15.67% compared to normal lines of Y – G and B – G at 353. kV and 1633 A. Then, for the 2L – G fault, again the voltage is reduced to zero and when fault clearance occurred, the R – G and Y – G lines experienced overvoltage and overcurrent at 570.4 kV and 708.5kV, which showed more than 60% transient compared to normal line B-G at 353.4 kV. In Contrast, the 3L – G fault causes all transmission lines to experience overvoltage and overcurrent at different times and can damage the whole transmission system. Thus, to reduce the severe impact of fault, the Inverse Definite Minimum Time Over Current (IDMT O/C) relay protection is installed in the line model.

Authors

Publication Details

Journal
Jurnal Kejuruteraan
Published
2025-01-29
DOI
https://doi.org/10.17576/jkukm-2025-37(1)-35
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modelling of 500 Kv Long Transmission Line and Fault Detection Using Inverse Definite Minimum Time Over Current (IDMT O/C) relay

S. Tarmizi, Nazatul Shima Moh Nazar, Abdul Rashid Abdul Rahman, Noor Fadzilah Mohamed Sharif et al.
Jurnal Kejuruteraan
Power Systems Fault Detection
article

A Modelling of 500 Kv Long Transmission Line and Fault Detection Using Inverse Definite Minimum Time Over Current (IDMT O/C) relay

S. Tarmizi, Nazatul Shima Moh Nazar, Abdul Rashid Abdul Rahman, Noor Fadzilah Mohamed Sharif, Buda Samaila, Khairun Neesya Mohamed Shafiee, Nur Fatin Izzati Tajudin
article en

Abstract

As electricity demand increases day by day due to economic growth, the process of transmitting efficient electrical power is vital. Thus, a power simulation study is required to determine the mechanism of the transmission line, and possible faults that occurred in the transmission line system. On a daily basis, single line to ground fault (L-G), double line to ground fault (2L-G), and triple line to ground fault (3L-G) are the faults that normally occur in the long transmission line system. In this project, a model of a 300km/500 kV EHV transmission line consisting of a three-phase source, distribution line, and load is simulated using MATLAB software. When the L – G fault is applied, the voltage is diminished to zero and upon fault clearance, the R – G line produced overvoltage and overcurrent by 518.9 kV and 1889 A, which increased about 46.83% and 15.67% compared to normal lines of Y – G and B – G at 353. kV and 1633 A. Then, for the 2L – G fault, again the voltage is reduced to zero and when fault clearance occurred, the R – G and Y – G lines experienced overvoltage and overcurrent at 570.4 kV and 708.5kV, which showed more than 60% transient compared to normal line B-G at 353.4 kV. In Contrast, the 3L – G fault causes all transmission lines to experience overvoltage and overcurrent at different times and can damage the whole transmission system. Thus, to reduce the severe impact of fault, the Inverse Definite Minimum Time Over Current (IDMT O/C) relay protection is installed in the line model.

Jurnal KejuruteraanVol. 37(1)
National Defence University of Malaysia
Openalex Percentile: Top 98%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.