Greener and rapid magnetic solid phase microextraction method using Fe3O4@Al2O3/AC for chromatographic determination of neonicotinoid pesticides in vegetable oils

A greener sample preparation method based on magnetic solid phase microextraction (MSPμE) was developed for the preconcentration of neonicotinoid pesticides (acetamiprid, imidacloprid, thiacloprid and thiamethoxam) in vegetable oil samples followed by separation and quantification using high performance liquid chromatography with diode array detector (HPLC-DAD). Different characterisation techniques such as Fourier Transform Infrared Spectroscopy (FTIR), Powder X-ray diffraction analysis (PXRD), Thermogravimetric Analysis (TGA), Transmission electron microscopy (TEM), and scanning electron microscope and energy-dispersive X-ray spectroscopy (SEM-EDS) confirmed the synthesised magnetic nano adsorbents (Fe 3 O 4 , Fe 3 O 4 @Al 2 O 3 and Fe 3 O 4 @Al 2 O 3 /AC). The most influential parameters affecting MSPμE of NEOs by Fe 3 O 4 @Al 2 O 3 /AC were examined using a multivariate optimisation approach and 8 min extraction time, 13 pH, 9 mg adsorbent mass, and 0.5 mL eluent volume were optimal parameters. The proposed Fe3O4@Al2O3/AC method showed high accuracy (80–119.21%) and precision (≤10 %) for all the investigated NEOs. Additionally, the obtained limit of detection (LOD) ranged from 0.5–1.76 ng µL -1 , the limit of quantification (LOQ) ranged from 1.87–6.62 ng µL -1 and satisfactory high preconcentration factors (73.02- 407.0) were comparable with literature reported studies. The Analytical GREEness calculator AGREE, BAGI and NEMI analysis confirmed greenness of MSPμE. After that, the validated MSPμE method was applied to real vegetable oil samples (avocado, canola, olive and sunflower), and fortunately, all the investigated NEOs were below LODs of the proposed MSPμE /HPLC-DAD methods.

Authors

Institutions

Publication Details

Journal
Advances in Sample Preparation
Published
2025-01-29
DOI
https://doi.org/10.1016/j.sampre.2025.100152
Citations
3
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
3.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Greener and rapid magnetic solid phase microextraction method using Fe3O4@Al2O3/AC for chromatographic determination of neonicotinoid pesticides in vegetable oils

Masixole Sihlahla, Philiswa N. Nomngongo, Nomvano Mketo, Musiiwa V. Sengane
3 citations
Advances in Sample Preparation
Pesticide Residue Analysis and Safety
3.49
article

Greener and rapid magnetic solid phase microextraction method using Fe3O4@Al2O3/AC for chromatographic determination of neonicotinoid pesticides in vegetable oils

Masixole Sihlahla, Philiswa N. Nomngongo, Nomvano Mketo, Musiiwa V. Sengane
article en
3 citations

Abstract

A greener sample preparation method based on magnetic solid phase microextraction (MSPμE) was developed for the preconcentration of neonicotinoid pesticides (acetamiprid, imidacloprid, thiacloprid and thiamethoxam) in vegetable oil samples followed by separation and quantification using high performance liquid chromatography with diode array detector (HPLC-DAD). Different characterisation techniques such as Fourier Transform Infrared Spectroscopy (FTIR), Powder X-ray diffraction analysis (PXRD), Thermogravimetric Analysis (TGA), Transmission electron microscopy (TEM), and scanning electron microscope and energy-dispersive X-ray spectroscopy (SEM-EDS) confirmed the synthesised magnetic nano adsorbents (Fe 3 O 4 , Fe 3 O 4 @Al 2 O 3 and Fe 3 O 4 @Al 2 O 3 /AC). The most influential parameters affecting MSPμE of NEOs by Fe 3 O 4 @Al 2 O 3 /AC were examined using a multivariate optimisation approach and 8 min extraction time, 13 pH, 9 mg adsorbent mass, and 0.5 mL eluent volume were optimal parameters. The proposed Fe3O4@Al2O3/AC method showed high accuracy (80–119.21%) and precision (≤10 %) for all the investigated NEOs. Additionally, the obtained limit of detection (LOD) ranged from 0.5–1.76 ng µL -1 , the limit of quantification (LOQ) ranged from 1.87–6.62 ng µL -1 and satisfactory high preconcentration factors (73.02- 407.0) were comparable with literature reported studies. The Analytical GREEness calculator AGREE, BAGI and NEMI analysis confirmed greenness of MSPμE. After that, the validated MSPμE method was applied to real vegetable oil samples (avocado, canola, olive and sunflower), and fortunately, all the investigated NEOs were below LODs of the proposed MSPμE /HPLC-DAD methods.

Advances in Sample PreparationVol. 13
University of South Africa (ZA), University of Johannesburg (ZA)
University of South Africa
Zero hunger
Openalex Percentile: Top 10%
Pesticide Residue Analysis and Safety
3.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.