Study of Gross alpha beta radioactivity content in commercial water brands by liquid scintillation

This study presents the Gross alpha beta radioactivity in bottled water from twenty different commercial brands. In Mexico, the official Mexican standard NOM-127-SSA1-2021 establishes the values of 0.5 and 1.0 Bq/L as limits for Gross alpha and beta radioactivity in drinking water. The analysis was carried out with the liquid scintillation method, making a concentration of 10 to obtain a minimum detectable concentration of 0.25 and 0.5 Bq/L respectively. The results obtained indicate that in all cases the bottled waters comply with the applicable standard, which in turn indicates that the effective annual dose would be less than 0.1 mSv, since this limit was calculated based on this premise, indicating that the radiological risk for the consumer is negligible according to this norm.

Authors

Institutions

Publication Details

Journal
Suplemento de la Revista Mexicana de Física
Published
2024-09-22
DOI
https://doi.org/10.31349/suplrevmexfis.5.011204
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Gross alpha beta radioactivity content in commercial water brands by liquid scintillation

Guillermo Delgado, Arturo Ángeles, C. P. Zepeda
Suplemento de la Revista Mexicana de Física
Radiation Detection and Scintillator Technologies
article

Study of Gross alpha beta radioactivity content in commercial water brands by liquid scintillation

Guillermo Delgado, Arturo Ángeles, C. P. Zepeda
article en

Abstract

This study presents the Gross alpha beta radioactivity in bottled water from twenty different commercial brands. In Mexico, the official Mexican standard NOM-127-SSA1-2021 establishes the values of 0.5 and 1.0 Bq/L as limits for Gross alpha and beta radioactivity in drinking water. The analysis was carried out with the liquid scintillation method, making a concentration of 10 to obtain a minimum detectable concentration of 0.25 and 0.5 Bq/L respectively. The results obtained indicate that in all cases the bottled waters comply with the applicable standard, which in turn indicates that the effective annual dose would be less than 0.1 mSv, since this limit was calculated based on this premise, indicating that the radiological risk for the consumer is negligible according to this norm.

Suplemento de la Revista Mexicana de FísicaVol. 5(1)
Instituto Nacional de Investigaciones Nucleares (MX)
Openalex Percentile: Top 65%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.