Fully-Gated Denoising Auto-Encoder for Artifact Reduction in ECG Signals

Cardiovascular diseases (CVDs) are the primary cause of death worldwide. For accurate diagnosis of CVDs, robust and efficient ECG denoising is particularly critical in ambulatory cases where various artifacts can degrade the quality of the ECG signal. None of the present denoising methods preserve the morphology of ECG signals adequately for all noise types, especially at high noise levels. This study proposes a novel Fully-Gated Denoising Autoencoder (FGDAE) to significantly reduce the effects of different artifacts on ECG signals. The proposed FGDAE utilizes gating mechanisms in all its layers, including skip connections, and employs Self-organized Operational Neural Network (self-ONN) neurons in its encoder. Furthermore, a multi-component loss function is proposed to learn efficient latent representations of ECG signals and provide reliable denoising with maximal morphological preservation. The proposed model is trained and benchmarked on the QT Database (QTDB), degraded by adding randomly mixed artifacts collected from the MIT-BIH Noise Stress Test Database (NSTDB). The FGDAE showed the best performance on all seven error metrics used in our work in different noise intensities and artifact combinations compared with state-of-the-art algorithms. Moreover, FGDAE provides reliable denoising in extreme conditions and for varied noise compositions. The significantly reduced model size, 61% to 73% reduction, compared with the state-of-the-art algorithm, and the inference speed of the FGDAE model provide evident benefits in various practical applications. While our model performs best compared with other models tested in this study, more improvements are needed for optimal morphological preservation, especially in the presence of electrode motion artifacts.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-01-29
DOI
https://doi.org/10.3390/s25030801
Citations
7
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
9.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fully-Gated Denoising Auto-Encoder for Artifact Reduction in ECG Signals

Ahmed Maher Abed Shaheen, Liang Ye, Tapio Seppänen, Chrishni Karunaratne
7 citations
Sensors
ECG Monitoring and Analysis
9.72
article

Fully-Gated Denoising Auto-Encoder for Artifact Reduction in ECG Signals

Ahmed Maher Abed Shaheen, Liang Ye, Tapio Seppänen, Chrishni Karunaratne
article en
7 citations

Abstract

Cardiovascular diseases (CVDs) are the primary cause of death worldwide. For accurate diagnosis of CVDs, robust and efficient ECG denoising is particularly critical in ambulatory cases where various artifacts can degrade the quality of the ECG signal. None of the present denoising methods preserve the morphology of ECG signals adequately for all noise types, especially at high noise levels. This study proposes a novel Fully-Gated Denoising Autoencoder (FGDAE) to significantly reduce the effects of different artifacts on ECG signals. The proposed FGDAE utilizes gating mechanisms in all its layers, including skip connections, and employs Self-organized Operational Neural Network (self-ONN) neurons in its encoder. Furthermore, a multi-component loss function is proposed to learn efficient latent representations of ECG signals and provide reliable denoising with maximal morphological preservation. The proposed model is trained and benchmarked on the QT Database (QTDB), degraded by adding randomly mixed artifacts collected from the MIT-BIH Noise Stress Test Database (NSTDB). The FGDAE showed the best performance on all seven error metrics used in our work in different noise intensities and artifact combinations compared with state-of-the-art algorithms. Moreover, FGDAE provides reliable denoising in extreme conditions and for varied noise compositions. The significantly reduced model size, 61% to 73% reduction, compared with the state-of-the-art algorithm, and the inference speed of the FGDAE model provide evident benefits in various practical applications. While our model performs best compared with other models tested in this study, more improvements are needed for optimal morphological preservation, especially in the presence of electrode motion artifacts.

SensorsVol. 25(3)
Harbin Institute of Technology (CN), University of Oulu (FI)
Business Finland
Openalex Percentile: Top 2%
ECG Monitoring and Analysis
9.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.