Precision of Photogrammetry and Intraoral Scanning in Full-Arch Implant Rehabilitation: An In Vitro Comparative Study

The objective of this in vitro study is to evaluate and compare the precision of digital impressions obtained using intraoral scanners and photogrammetry devices for full-arch implant-supported oral rehabilitation. Three reference models were created with various spatial distributions of Straumann implants, according to the Caramês I Classification: (i) option A with six implants; (ii) option B with four implants; and (iii) option C with four implants. Thirty digital impressions were taken for each of the reference models: ten with the Intraoral 3Shape Trios 3 scanner, ten with the Medit i500 intraoral scanner, and ten with the PIC Dental photogrammetry device. Intra-group best-fit overlaps were performed between the virtual models obtained, and accuracy was evaluated using root mean square (RMS) values. A significance level of p = 0.05 was defined. Mean values were statistically analyzed using the Kruskal–Wallis test. All scanners studied showed high precision, with RMS values similar for each implant distribution. The PIC Dental photogrammetry device demonstrated the best results for the CCI A and B distributions, with mean values of 11.28 µm and 14.44 µm, respectively. For the CCI C distribution, the 3Shape Trios 3 scanner achieved the best result, with a mean value of 5.96 µm. Among all devices, the implant distribution showing the highest RMS values was the CCI B, with mean values between 14.44 µm and 16.96 µm. The PIC Dental device was the only method that did not exhibit statistically significant differences in RMS values across the different distributions studied, indicating that its performance is unaffected by distribution variations. No statistically significant differences (p < 0.05) were observed in the RMS values among the three types of scanners. Overall, a smaller number of implants and closer distribution between them resulted in improved precision for digital impressions in full-arch implant rehabilitation.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-01-29
DOI
https://doi.org/10.3390/app15031388
Citations
4
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
7.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision of Photogrammetry and Intraoral Scanning in Full-Arch Implant Rehabilitation: An In Vitro Comparative Study

Maria Helena Figueiral, Susana Oliveira, Manuel António Sampaio-Fernandes, J.C. Sampaio-Fernandes et al.
4 citations
Applied Sciences
Dental Implant Techniques and Outcomes
7.16
article

Precision of Photogrammetry and Intraoral Scanning in Full-Arch Implant Rehabilitation: An In Vitro Comparative Study

Maria Helena Figueiral, Susana Oliveira, Manuel António Sampaio-Fernandes, J.C. Sampaio-Fernandes, Joao Carlos Lázaro Faria, Rodrigo Malheiro
article en
4 citations

Abstract

The objective of this in vitro study is to evaluate and compare the precision of digital impressions obtained using intraoral scanners and photogrammetry devices for full-arch implant-supported oral rehabilitation. Three reference models were created with various spatial distributions of Straumann implants, according to the Caramês I Classification: (i) option A with six implants; (ii) option B with four implants; and (iii) option C with four implants. Thirty digital impressions were taken for each of the reference models: ten with the Intraoral 3Shape Trios 3 scanner, ten with the Medit i500 intraoral scanner, and ten with the PIC Dental photogrammetry device. Intra-group best-fit overlaps were performed between the virtual models obtained, and accuracy was evaluated using root mean square (RMS) values. A significance level of p = 0.05 was defined. Mean values were statistically analyzed using the Kruskal–Wallis test. All scanners studied showed high precision, with RMS values similar for each implant distribution. The PIC Dental photogrammetry device demonstrated the best results for the CCI A and B distributions, with mean values of 11.28 µm and 14.44 µm, respectively. For the CCI C distribution, the 3Shape Trios 3 scanner achieved the best result, with a mean value of 5.96 µm. Among all devices, the implant distribution showing the highest RMS values was the CCI B, with mean values between 14.44 µm and 16.96 µm. The PIC Dental device was the only method that did not exhibit statistically significant differences in RMS values across the different distributions studied, indicating that its performance is unaffected by distribution variations. No statistically significant differences (p < 0.05) were observed in the RMS values among the three types of scanners. Overall, a smaller number of implants and closer distribution between them resulted in improved precision for digital impressions in full-arch implant rehabilitation.

Applied SciencesVol. 15(3)
University of Lisbon (PT), Universidade do Porto (PT), Institute of Mechanical Engineering and Industrial Mangement (PT)
Openalex Percentile: Top 4%
Dental Implant Techniques and Outcomes
7.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.