Treatment of mandibular condyle fractures with a rhombic 3D condylar fracture plate – Does the surgical approach matter?

Fractures involving the mandibular condyle are a significant subset of mandibular fractures, demanding specialized implant design considerations for effective surgical treatment. The core objective of this study was to assess the clinical and radiographic results in patients treated with a single rhombic-shaped implant according to the surgical approach used. This retrospective cohort investigation, spanning a ten-year recruitment window, included individuals with unilateral fractures who underwent surgical treatment with a rhombic-shaped implant. These patients were subject to follow-up examinations at one, three, and six months post-surgery, along with corresponding orthopantomograms and clinical assessments. Patients were allocated into four groups depending on the fracture pattern and level as well as the approach used for fracture treatment. The primary outcome variables under scrutiny encompassed parameters such as occlusion, maximum interincisal distance, mandibular excursion across different postoperative time points, and radiographic measurements of mandibular height and the gonion angle. A total of 236 patients, comprising 161 males and 75 females, with an average age of 40.2 ± 19.2 years, were included in the study. Satisfactory occlusion was exhibited in 99.6% of patients at the six-month follow-up. Furthermore, all parameters associated with mandibular excursion displayed significant enhancements (p < 0.01). These improvements were accompanied by a reduction in ramus height and increased gonion angle on the fractured side. The investigation of the clinical and radiographic results suggest a tendency of the choice of the approach depending on the fracture pattern, but no statistically significant recommendations could be identified.

Authors

Institutions

Publication Details

Journal
Journal of Cranio-Maxillofacial Surgery
Published
2025-01-29
DOI
https://doi.org/10.1016/j.jcms.2025.01.029
Citations
1
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment of mandibular condyle fractures with a rhombic 3D condylar fracture plate – Does the surgical approach matter?

Adrian Franke, H Leonhardt, Christian Bräuer, Bernhard Remschmidt et al.
1 citations
Journal of Cranio-Maxillofacial Surgery
Facial Trauma and Fracture Management
2.01
article

Treatment of mandibular condyle fractures with a rhombic 3D condylar fracture plate – Does the surgical approach matter?

Adrian Franke, H Leonhardt, Christian Bräuer, Bernhard Remschmidt, Niall McLeod, Jan Matschke, Günter Lauer
article en
1 citations

Abstract

Fractures involving the mandibular condyle are a significant subset of mandibular fractures, demanding specialized implant design considerations for effective surgical treatment. The core objective of this study was to assess the clinical and radiographic results in patients treated with a single rhombic-shaped implant according to the surgical approach used. This retrospective cohort investigation, spanning a ten-year recruitment window, included individuals with unilateral fractures who underwent surgical treatment with a rhombic-shaped implant. These patients were subject to follow-up examinations at one, three, and six months post-surgery, along with corresponding orthopantomograms and clinical assessments. Patients were allocated into four groups depending on the fracture pattern and level as well as the approach used for fracture treatment. The primary outcome variables under scrutiny encompassed parameters such as occlusion, maximum interincisal distance, mandibular excursion across different postoperative time points, and radiographic measurements of mandibular height and the gonion angle. A total of 236 patients, comprising 161 males and 75 females, with an average age of 40.2 ± 19.2 years, were included in the study. Satisfactory occlusion was exhibited in 99.6% of patients at the six-month follow-up. Furthermore, all parameters associated with mandibular excursion displayed significant enhancements (p < 0.01). These improvements were accompanied by a reduction in ramus height and increased gonion angle on the fractured side. The investigation of the clinical and radiographic results suggest a tendency of the choice of the approach depending on the fracture pattern, but no statistically significant recommendations could be identified.

Journal of Cranio-Maxillofacial SurgeryVol. 53(5)
Medical University of Graz (AT), University Hospitals Coventry and Warwickshire NHS Trust (GB), Universitätsmedizin Rostock (DE), University Hospital Carl Gustav Carus (DE), Technische Universität Dresden (DE)
Openalex Percentile: Top 19%
Facial Trauma and Fracture Management
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.