Transimpedance Matrix Measurement (TIM) Parameters Evaluation for the Assessment of Cochlear Implant Electrode Placement and Modiolar Proximity in Children

<b>Introduction</b>: Transimpedance matrix measurement (TIM) is an electrophysiological measurement protocol of the impedance patterns of electrode contacts within the cochlea. Several studies have reported that TIM is an effective tool for the identification of abnormal electrode array placement. However, the normative values for properly inserted electrodes, as well as correlation of the TIM patterns with the electrode position, are not completely determined. <b>Objectives</b>: The first aim of this study is to establish normative values of TIM measurements obtained in children with proper electrode array insertion and tip fold-over, with proper inner ear anatomy and in congenital anomalies. The second aim of this study is to compare TIM measurements in Slim Modiolar (SM) and in Contour Advance (CA) electrodes, as their position is different according to the modiolus proximity. <b>Methods</b>: A total of 55 pediatric patients were included in the study and underwent cochlear implantation. 62 intraoperative measurements were conducted in this group-50 in children with normal inner ear anatomy and 12 in children with inner ear malformations. After each implantation, a plain x-ray was obtained. <b>Results</b>: There were clear statistically significant differences in TIM patterns in patients where electrode fold-over was confirmed and between SM and CA electrodes. <b>Conclusions:</b> TIM is a promising technique for intraoperative analysis of electrode placement. TIM patterns differ and correlate consistently with the different models of array implanted. This study is the first to report TIM patterns observed in children with normal inner ear anatomy and in inner ear malformations.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2025-01-29
DOI
https://doi.org/10.3390/biomedicines13020319
Citations
6
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
8.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transimpedance Matrix Measurement (TIM) Parameters Evaluation for the Assessment of Cochlear Implant Electrode Placement and Modiolar Proximity in Children

Józef Mierzwiński, Karolina Haber, Andrew J. Fishman, Katarzyna Radomska et al.
6 citations
Biomedicines
Hearing Loss and Rehabilitation
8.59
article

Transimpedance Matrix Measurement (TIM) Parameters Evaluation for the Assessment of Cochlear Implant Electrode Placement and Modiolar Proximity in Children

Józef Mierzwiński, Karolina Haber, Andrew J. Fishman, Katarzyna Radomska, Marcin Talar, Paulina Mierzwińska-Dolny
article en
6 citations

Abstract

<b>Introduction</b>: Transimpedance matrix measurement (TIM) is an electrophysiological measurement protocol of the impedance patterns of electrode contacts within the cochlea. Several studies have reported that TIM is an effective tool for the identification of abnormal electrode array placement. However, the normative values for properly inserted electrodes, as well as correlation of the TIM patterns with the electrode position, are not completely determined. <b>Objectives</b>: The first aim of this study is to establish normative values of TIM measurements obtained in children with proper electrode array insertion and tip fold-over, with proper inner ear anatomy and in congenital anomalies. The second aim of this study is to compare TIM measurements in Slim Modiolar (SM) and in Contour Advance (CA) electrodes, as their position is different according to the modiolus proximity. <b>Methods</b>: A total of 55 pediatric patients were included in the study and underwent cochlear implantation. 62 intraoperative measurements were conducted in this group-50 in children with normal inner ear anatomy and 12 in children with inner ear malformations. After each implantation, a plain x-ray was obtained. <b>Results</b>: There were clear statistically significant differences in TIM patterns in patients where electrode fold-over was confirmed and between SM and CA electrodes. <b>Conclusions:</b> TIM is a promising technique for intraoperative analysis of electrode placement. TIM patterns differ and correlate consistently with the different models of array implanted. This study is the first to report TIM patterns observed in children with normal inner ear anatomy and in inner ear malformations.

BiomedicinesVol. 13(2)
Military Medical Academy (RS), Nicolaus Copernicus University (PL), University of Bydgoszcz (PL), University of Missouri (US), Pomeranian Medical University (PL)
Openalex Percentile: Top 2%
Hearing Loss and Rehabilitation
8.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.