P-254. The Effect of Disinfection with 222-nm Ultraviolet C on Surfaces Contaminated with <i>Clostridioides difficile</i> and Vancomycin-resistant Enterococci in the Bathrooms of Isolation Patients

Abstract Background Contaminated environmental surfaces are important sources of transmission for healthcare-associated pathogens, including Clostridioides difficile (CD) and vancomycin-resistant enterococci (VRE). Toilet surfaces are easily contaminated by pathogens excreted in stools. In this study, we investigated the efficacy of a 222-nm ultraviolet C (UVC) disinfection device, Care222®, for removing bacterial contamination in the bathrooms of isolated patients. Methods This study was conducted in the rooms of five patients diagnosed with C. difficile infection and in the rooms of five patients colonized with VRE. The Care222® device is mounted on a mobile cart and fixed at a 45-degree downward angle. The Care222® emission window was placed 1 m from the farthest end of the toilet seat and at a height of 1.1 m from the floor. At this position, UVC irradiation was performed for 45 min at a total 222-nm UVC fluence of 27 mJ/cm2. Before and after UVC irradiation, samples were collected from the toilet seat and control panel of the electric warm-water bidet toilet seat, in each room, and colony-forming units (CFUs) were determined. Results Disinfection with 222-nm UVC resulted in a significant decrease in the number of CD CFUs compared to the number of CFUs before disinfection (Median CFUs (range), 8 (0–51) vs. 1 (0-5), P=0.004). It also resulted in a significant decrease in the number of VRE CFUs compared to the number of CFUs before disinfection (Median CFUs (range), 7 (1–32) vs. 1 (0-3), P=0.001). Conclusion The disinfection with the 222-nm UVC device significantly reduced CD and VRE surface contamination in the bathrooms of isolated patients. Further studies are required to investigate the effectiveness of 222-nm UVC disinfection for reducing environmental pathogen contamination. Disclosures All Authors: No reported disclosures

Authors

Institutions

Publication Details

Journal
Open Forum Infectious Diseases
Published
2025-01-29
DOI
https://doi.org/10.1093/ofid/ofae631.458
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P-254. The Effect of Disinfection with 222-nm Ultraviolet C on Surfaces Contaminated with Clostridioides difficile and Vancomycin-resistant Enterococci in the Bathrooms of Isolation Patients

Kayoko Tadera, Hiroki Ohge, Norifumi Shigemoto, Toshihito Nomura et al.
1 links
Open Forum Infectious Diseases
Infection Control and Ventilation
article

P-254. The Effect of Disinfection with 222-nm Ultraviolet C on Surfaces Contaminated with Clostridioides difficile and Vancomycin-resistant Enterococci in the Bathrooms of Isolation Patients

Kayoko Tadera, Hiroki Ohge, Norifumi Shigemoto, Toshihito Nomura, Hiroki Kitagawa, Keitaro Omori
article en

Abstract

Abstract Background Contaminated environmental surfaces are important sources of transmission for healthcare-associated pathogens, including Clostridioides difficile (CD) and vancomycin-resistant enterococci (VRE). Toilet surfaces are easily contaminated by pathogens excreted in stools. In this study, we investigated the efficacy of a 222-nm ultraviolet C (UVC) disinfection device, Care222®, for removing bacterial contamination in the bathrooms of isolated patients. Methods This study was conducted in the rooms of five patients diagnosed with C. difficile infection and in the rooms of five patients colonized with VRE. The Care222® device is mounted on a mobile cart and fixed at a 45-degree downward angle. The Care222® emission window was placed 1 m from the farthest end of the toilet seat and at a height of 1.1 m from the floor. At this position, UVC irradiation was performed for 45 min at a total 222-nm UVC fluence of 27 mJ/cm2. Before and after UVC irradiation, samples were collected from the toilet seat and control panel of the electric warm-water bidet toilet seat, in each room, and colony-forming units (CFUs) were determined. Results Disinfection with 222-nm UVC resulted in a significant decrease in the number of CD CFUs compared to the number of CFUs before disinfection (Median CFUs (range), 8 (0–51) vs. 1 (0-5), P=0.004). It also resulted in a significant decrease in the number of VRE CFUs compared to the number of CFUs before disinfection (Median CFUs (range), 7 (1–32) vs. 1 (0-3), P=0.001). Conclusion The disinfection with the 222-nm UVC device significantly reduced CD and VRE surface contamination in the bathrooms of isolated patients. Further studies are required to investigate the effectiveness of 222-nm UVC disinfection for reducing environmental pathogen contamination. Disclosures All Authors: No reported disclosures

Open Forum Infectious DiseasesVol. 12(Supplement_1)
Hiroshima University Hospital (JP)
Openalex Percentile: Top 98%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.