P-257. Effectiveness of Pulsed-Xenon Ultraviolet Disinfection during Terminal Cleaning of Patient Rooms in the Intensive Care Unit on the Sustained Containment of Drug-resistant <i>Acinetobacter baumannii</i>

Abstract Background Environmental disinfection by ultraviolet (UV) has been shown to be effective in controlling transmission of multidrug-resistant organisms, and introduced into daily practices in addition to manual terminal cleaning in some hospitals in the US. However, its effectiveness outside the US healthcare setting is not well investigated. Moreover, its effectiveness to control gram-negative bacteria has not been well described. Methods This study was conducted in the intensive care unit (ICU) of Yamagata University Hospital, a 637-bed tertiary referral hospital. Sporadic transmission of two drug-resistant Acinetobacter baumannii (2DRA) began in late 2013. Despite intensified hand hygiene promotion and manual terminal cleaning, transmission of 2DRA continued. In January 2018, we added pulsed-xenon ultraviolet (PX-UV) disinfection for the terminal cleaning after every patient discharge. The study periods were defined as follows: the baseline period (August 2016 to January 2018, manual cleaning only) and the intervention period (February 2018 to December 2023, addition of PX-UV). All patients admitted in the ICU were regularly screened for 2DRA for the detection of possible acquisition of 2DRA throughout the study periods. Results The incidence of acquisition of 2DRA in the ICU significantly declined (4.45 per 1,000 patient days in the baseline period to 1.09 in the intervention period, relative risk (RR): 0.26, 95% confidence interval: 0.12-0.51). Cases in the intervention period were sporadic, and no cluster was found. In contrast, in non-ICU wards, where PX-UV disinfection was performed only after the discharge of patients known to be colonized or infected with 2DRA or other multidrug-resistant pathogens, possible transmission of 2DRA was observed several times. Conclusion Adding PX-UV after manual terminal cleaning was effective in controlling acquisition of 2DRA in the ICU patients. The effectiveness of PX-UV in controlling gram-negative MDROs in the non-US healthcare settings is suggested. In contrast, there was room for improvement in controlling of 2DRA in non-intervention wards. Disclosures All Authors: No reported disclosures

Authors

Institutions

Publication Details

Journal
Open Forum Infectious Diseases
Published
2025-01-29
DOI
https://doi.org/10.1093/ofid/ofae631.461
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P-257. Effectiveness of Pulsed-Xenon Ultraviolet Disinfection during Terminal Cleaning of Patient Rooms in the Intensive Care Unit on the Sustained Containment of Drug-resistant Acinetobacter baumannii

Jun Yakuwa, Keita Morikane, Masaki Nakane
Open Forum Infectious Diseases
Medical Device Sterilization and Disinfection
article

P-257. Effectiveness of Pulsed-Xenon Ultraviolet Disinfection during Terminal Cleaning of Patient Rooms in the Intensive Care Unit on the Sustained Containment of Drug-resistant Acinetobacter baumannii

Jun Yakuwa, Keita Morikane, Masaki Nakane
article en

Abstract

Abstract Background Environmental disinfection by ultraviolet (UV) has been shown to be effective in controlling transmission of multidrug-resistant organisms, and introduced into daily practices in addition to manual terminal cleaning in some hospitals in the US. However, its effectiveness outside the US healthcare setting is not well investigated. Moreover, its effectiveness to control gram-negative bacteria has not been well described. Methods This study was conducted in the intensive care unit (ICU) of Yamagata University Hospital, a 637-bed tertiary referral hospital. Sporadic transmission of two drug-resistant Acinetobacter baumannii (2DRA) began in late 2013. Despite intensified hand hygiene promotion and manual terminal cleaning, transmission of 2DRA continued. In January 2018, we added pulsed-xenon ultraviolet (PX-UV) disinfection for the terminal cleaning after every patient discharge. The study periods were defined as follows: the baseline period (August 2016 to January 2018, manual cleaning only) and the intervention period (February 2018 to December 2023, addition of PX-UV). All patients admitted in the ICU were regularly screened for 2DRA for the detection of possible acquisition of 2DRA throughout the study periods. Results The incidence of acquisition of 2DRA in the ICU significantly declined (4.45 per 1,000 patient days in the baseline period to 1.09 in the intervention period, relative risk (RR): 0.26, 95% confidence interval: 0.12-0.51). Cases in the intervention period were sporadic, and no cluster was found. In contrast, in non-ICU wards, where PX-UV disinfection was performed only after the discharge of patients known to be colonized or infected with 2DRA or other multidrug-resistant pathogens, possible transmission of 2DRA was observed several times. Conclusion Adding PX-UV after manual terminal cleaning was effective in controlling acquisition of 2DRA in the ICU patients. The effectiveness of PX-UV in controlling gram-negative MDROs in the non-US healthcare settings is suggested. In contrast, there was room for improvement in controlling of 2DRA in non-intervention wards. Disclosures All Authors: No reported disclosures

Open Forum Infectious DiseasesVol. 12(Supplement_1)
Yamagata University Hospital (JP)
Openalex Percentile: Top 98%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.