A 5.76GS/s 180MHz-BW 74.1dB-DR 2x TI Extrapolated CT DSM with Broadband Hybrid-Inputs Current-Mode Adder in 28nm CMOS

In recent years, Gigahertz-rate oversampled CT DSMs have been consistently explored to pursue a larger bandwidth (BW) [1] –[4]. Note that the usable oversampling ratio (OSR) is seriously limited (i.e. below 10) in those works owing to the restrained clock rate. A low OSR results in poor quantization efficiency, thus limiting the achievable dynamic range (DR). In such an ultra-low-OSR context, multi-stage noise-shaping (MASH) topology [2–3] can achieve $\sim 70 \mathrm{~dB}$ DR at 360 MHz and 465 MHz BWs, respectively. However, those broadband MASH CT DSMs significantly suffer from quantization noise (QN) leakage, requiring digital calibrations, which consume large power and area.

Authors

Institutions

Publication Details

Published
2024-11-18
DOI
https://doi.org/10.1109/a-sscc60305.2024.10848641
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 5.76GS/s 180MHz-BW 74.1dB-DR 2x TI Extrapolated CT DSM with Broadband Hybrid-Inputs Current-Mode Adder in 28nm CMOS

Liang Qi, Mingqiang Guo, Meng Guo, Sai‐Weng Sin et al.
Medical Imaging Techniques and Applications
article

A 5.76GS/s 180MHz-BW 74.1dB-DR 2x TI Extrapolated CT DSM with Broadband Hybrid-Inputs Current-Mode Adder in 28nm CMOS

Liang Qi, Mingqiang Guo, Meng Guo, Sai‐Weng Sin, Zhichao Tan, Yan Liu, Yuekai Liu, Yichen Jin
article en

Abstract

In recent years, Gigahertz-rate oversampled CT DSMs have been consistently explored to pursue a larger bandwidth (BW) [1] –[4]. Note that the usable oversampling ratio (OSR) is seriously limited (i.e. below 10) in those works owing to the restrained clock rate. A low OSR results in poor quantization efficiency, thus limiting the achievable dynamic range (DR). In such an ultra-low-OSR context, multi-stage noise-shaping (MASH) topology [2–3] can achieve $\sim 70 \mathrm{~dB}$ DR at 360 MHz and 465 MHz BWs, respectively. However, those broadband MASH CT DSMs significantly suffer from quantization noise (QN) leakage, requiring digital calibrations, which consume large power and area.

Shanghai Jiao Tong University (CN), University of Macau (MO), Zhejiang University (CN)
National Key Research and Development Program of China, Technology Development
Affordable and clean energy
Openalex Percentile: Top 57%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.