Lessons we Have Learnt on the Stages of an A-Mode Us Prosthetic Control Interface

The research and development of Ultrasound (US) interfaces for prosthetic hand control has seen an increase in the past few years. Among the reasons for this rise is the capacity of easy detection of the state of deep muscles that are almost invisible to the standard electromyography. The two main modes of Ultrasound operation for this task are Amplitude mode (A-mode) and Brightness mode (B-mode). While B-mode can accurately represent the tissue state (as a 2D image of the forearm section), due to its bulkiness and greater computational costs, the application of A-mode for sonomyography is increasing (which results in vectorized data along the intersecting line of each individual transducers). In contrast to B-mode systems, a multichannel A-mode US system can be built from roughly a half dozen ICs and its size could be as small as a couple of coins, perfect for wearable applications. This paper explores which are these required ICs, what design considerations should be taken when choosing them and what are the test setups one could use to individually test each component.

Authors

Institutions

Publication Details

Published
2024-11-18
DOI
https://doi.org/10.1109/icecs61496.2024.10849127
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lessons we Have Learnt on the Stages of an A-Mode Us Prosthetic Control Interface

Miklós Koller, JÚLIO ANTONIO MORAES DE ALMEIDA
Muscle activation and electromyography studies
article

Lessons we Have Learnt on the Stages of an A-Mode Us Prosthetic Control Interface

Miklós Koller, JÚLIO ANTONIO MORAES DE ALMEIDA
article en

Abstract

The research and development of Ultrasound (US) interfaces for prosthetic hand control has seen an increase in the past few years. Among the reasons for this rise is the capacity of easy detection of the state of deep muscles that are almost invisible to the standard electromyography. The two main modes of Ultrasound operation for this task are Amplitude mode (A-mode) and Brightness mode (B-mode). While B-mode can accurately represent the tissue state (as a 2D image of the forearm section), due to its bulkiness and greater computational costs, the application of A-mode for sonomyography is increasing (which results in vectorized data along the intersecting line of each individual transducers). In contrast to B-mode systems, a multichannel A-mode US system can be built from roughly a half dozen ICs and its size could be as small as a couple of coins, perfect for wearable applications. This paper explores which are these required ICs, what design considerations should be taken when choosing them and what are the test setups one could use to individually test each component.

Pázmány Péter Catholic University (HU)
National Research Center "Kurchatov Institute"
Openalex Percentile: Top 76%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lessons we Have Learnt on the Stages of an A-Mode Us Prosthetic Control Interface — Miklós Koller, JÚLIO ANTONIO MORAES DE ALMEIDA · (2024) | TGRS Research Map | TGRS