A Frequency-Division Multiplexed 16-Channel AFE for Wearable MC-sEMG Recording

This paper presents a 16 -channel analog frontend (AFE) for wearable multi-channel surface electromyography recording. The proposed architecture adopts frequency-division multiplexing (FDM), enabling extensive sharing of signal conditioning circuitry and requiring only three cables for transmission to an external back-end for digital signal processing. Benefiting from the up-conversion process, the FDM signal exhibits robustness against cable motion artifacts and mains interference, allowing short-distance communication without compromising signal quality. This work achieves a channel-to-cable ratio of 16:3, dramatically reducing system complexity. Implemented in a 180 nm CMOS technology, the proposed 16-channel AFE occupies only <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$6.42 ~\text{mm}^{2}$</tex> and consumes <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$40.1 \mu ~\mathrm{W}$</tex> per channel from a 1.5 V supply. Measurements on a forearm demonstrate the capability to simultaneously detect muscle activation from various muscle groups, showcasing its potential for gesture recognition applications.

Authors

Institutions

Publication Details

Published
2024-11-18
DOI
https://doi.org/10.1109/icecs61496.2024.10848532
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Frequency-Division Multiplexed 16-Channel AFE for Wearable MC-sEMG Recording

Yu-Kai Huang, Ana Rusu, Saul Rodriguez, Alejandro D. Fernandez Schrunder
Muscle activation and electromyography studies
article

A Frequency-Division Multiplexed 16-Channel AFE for Wearable MC-sEMG Recording

Yu-Kai Huang, Ana Rusu, Saul Rodriguez, Alejandro D. Fernandez Schrunder
article en

Abstract

This paper presents a 16 -channel analog frontend (AFE) for wearable multi-channel surface electromyography recording. The proposed architecture adopts frequency-division multiplexing (FDM), enabling extensive sharing of signal conditioning circuitry and requiring only three cables for transmission to an external back-end for digital signal processing. Benefiting from the up-conversion process, the FDM signal exhibits robustness against cable motion artifacts and mains interference, allowing short-distance communication without compromising signal quality. This work achieves a channel-to-cable ratio of 16:3, dramatically reducing system complexity. Implemented in a 180 nm CMOS technology, the proposed 16-channel AFE occupies only <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$6.42 ~\text{mm}^{2}$</tex> and consumes <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$40.1 \mu ~\mathrm{W}$</tex> per channel from a 1.5 V supply. Measurements on a forearm demonstrate the capability to simultaneously detect muscle activation from various muscle groups, showcasing its potential for gesture recognition applications.

KTH Royal Institute of Technology (SE)
Affordable and clean energy
Openalex Percentile: Top 76%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.