Increase Resilience Of Uninterruptible Power Supply Against Network Disturbance

Serious problems can be posed by exceeding the allowable limit of overvoltage in AC circuits, which is a significant issue. A simplified configuration is proposed in this paper to address sudden voltage surges and prevent voltage exceeding permissible thresholds for operating single-phase (UPS) devices after reviewing previous researches that relies on effective protection against transient surge and protection from overvoltage. This enhances the resiliency of UPS devices to various voltage fluctuations in the electrical grid. The proposed approach is split into two parts, with the first one, a back-to-back MOSFET is incorporated in series with the load to protect it by cutting off the current from the load during overvoltage occurrences. The second part involves a back-to-back MOSFET in series with a snubber circuit, connected in parallel with the load to operate as an active snubber circuit during transient surges. Several electrical grid disturbances are analyzed in the study using MATLAB. The simulation outcomes prove that the new configuration is effective in managing sudden voltage surges, constrains their magnitude, and disconnects the voltage from the UPS if it persists in exceeding the permissible limits. Additionally, the results from the overvoltage protection experiment indicate that the suggested control circuit effectively isolates the load from the circuit when the utility voltage surpasses the safe range for over 100ms.

Authors

Institutions

Publication Details

Published
2024-12-17
DOI
https://doi.org/10.1109/mepcon63025.2024.10850119
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increase Resilience Of Uninterruptible Power Supply Against Network Disturbance

Ibrahim M. Safwat, Ibrahim Abdelsalam, Muneera Yousif, Y. Elkoteshy
Smart Grid Security and Resilience
article

Increase Resilience Of Uninterruptible Power Supply Against Network Disturbance

Ibrahim M. Safwat, Ibrahim Abdelsalam, Muneera Yousif, Y. Elkoteshy
article en

Abstract

Serious problems can be posed by exceeding the allowable limit of overvoltage in AC circuits, which is a significant issue. A simplified configuration is proposed in this paper to address sudden voltage surges and prevent voltage exceeding permissible thresholds for operating single-phase (UPS) devices after reviewing previous researches that relies on effective protection against transient surge and protection from overvoltage. This enhances the resiliency of UPS devices to various voltage fluctuations in the electrical grid. The proposed approach is split into two parts, with the first one, a back-to-back MOSFET is incorporated in series with the load to protect it by cutting off the current from the load during overvoltage occurrences. The second part involves a back-to-back MOSFET in series with a snubber circuit, connected in parallel with the load to operate as an active snubber circuit during transient surges. Several electrical grid disturbances are analyzed in the study using MATLAB. The simulation outcomes prove that the new configuration is effective in managing sudden voltage surges, constrains their magnitude, and disconnects the voltage from the UPS if it persists in exceeding the permissible limits. Additionally, the results from the overvoltage protection experiment indicate that the suggested control circuit effectively isolates the load from the circuit when the utility voltage surpasses the safe range for over 100ms.

Military Technical College (EG), Arab Academy for Science, Technology, and Maritime Transport (EG)
Affordable and clean energy
Openalex Percentile: Top 68%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Increase Resilience Of Uninterruptible Power Supply Against Network Disturbance — Ibrahim M. Safwat, Ibrahim Abdelsalam, et al. · (2024) | TGRS Research Map | TGRS