Investigation of chromatographic procedures for the analysis of cationic impurities in uranium and plutonium matrices by ICP-OES and ICP-MS

Four different separation protocols were tested to analyze several cations in a U-Pu matrix by inductively coupled plasma – optical emission spectrometry (ICP-OES) or mass spectrometry (ICP-MS): UTEVA resin with HNO 3 eluent, UTEVA resin with HNO 3 /H 2 C 2 O 4 eluent, UTEVA resin with HNO 3 /H 2 O 2 eluent and TEVA resin with HNO 3 eluent. It was shown that none of the twenty nine tested cations (Al, Ag, B, Ca, Cd, Ce, Cr, Cu, Fe, Ga, La, Mg, Mn, Mo, Na, Nd, Ni, Pb, Pd, Rh, Sb, Se, Si, Sn, Sr, Ti, V, Y and Zn) was retained onto the resin, with recovery yields between 80 and 120 %. Meanwhile, the U-Pu matrix was retained onto the resin and was eliminated from the fraction containing the cations. After initial testing, two of the protocols were chosen: UTEVA resin with HNO 3 /H 2 C 2 O 4 eluent and UTEVA resin with HNO 3 /H 2 O 2 eluent thanks to their efficacy and practicality. Then, the two selected protocols were applied to a uranium oxide certified reference material to validate them. Twenty three out of the thirty one impurities presents in the material (Ag, Ba, Be, Bi, Cd, Co, Cr, Cu, Dy, Eu, Fe, Gd, In, Li, Mo, Ni, Pb, Sm, Sn, Ti, V, W and Zr) were determined with good recoveries. Th was fixed onto the resin. Based on theses results, it seems possible to analyze the forty one impurities in a U-Pu material by optimizing the operating conditions. These two protocols were used to study the presence of impurities in a Pu-based material to ensure the purity of the materials. Detection limits in the order of μg g −1 powder were obtained. • Efficient separation of cationic impurities in U-Pu matrix. • Chromatographic technique to separate cations from U, Pu and Th using UTEVA resin. • Measurement of trace and ultra-trace cations in U-Pu matrix by ICP-OES and ICP-MS.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part B Atomic Spectroscopy
Published
2025-01-29
DOI
https://doi.org/10.1016/j.sab.2025.107136
Citations
3
Primary Topic
Radioactive element chemistry and processing
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of chromatographic procedures for the analysis of cationic impurities in uranium and plutonium matrices by ICP-OES and ICP-MS

M. Garcia-Alcala Hernandez, Sarah Baghdadi, Christophe Maillard, Alexandre Quémet et al.
3 citations
Spectrochimica Acta Part B Atomic Spectroscopy
Radioactive element chemistry and processing
1.61
article

Investigation of chromatographic procedures for the analysis of cationic impurities in uranium and plutonium matrices by ICP-OES and ICP-MS

M. Garcia-Alcala Hernandez, Sarah Baghdadi, Christophe Maillard, Alexandre Quémet, Laure Montreuil
article en
3 citations

Abstract

Four different separation protocols were tested to analyze several cations in a U-Pu matrix by inductively coupled plasma – optical emission spectrometry (ICP-OES) or mass spectrometry (ICP-MS): UTEVA resin with HNO 3 eluent, UTEVA resin with HNO 3 /H 2 C 2 O 4 eluent, UTEVA resin with HNO 3 /H 2 O 2 eluent and TEVA resin with HNO 3 eluent. It was shown that none of the twenty nine tested cations (Al, Ag, B, Ca, Cd, Ce, Cr, Cu, Fe, Ga, La, Mg, Mn, Mo, Na, Nd, Ni, Pb, Pd, Rh, Sb, Se, Si, Sn, Sr, Ti, V, Y and Zn) was retained onto the resin, with recovery yields between 80 and 120 %. Meanwhile, the U-Pu matrix was retained onto the resin and was eliminated from the fraction containing the cations. After initial testing, two of the protocols were chosen: UTEVA resin with HNO 3 /H 2 C 2 O 4 eluent and UTEVA resin with HNO 3 /H 2 O 2 eluent thanks to their efficacy and practicality. Then, the two selected protocols were applied to a uranium oxide certified reference material to validate them. Twenty three out of the thirty one impurities presents in the material (Ag, Ba, Be, Bi, Cd, Co, Cr, Cu, Dy, Eu, Fe, Gd, In, Li, Mo, Ni, Pb, Sm, Sn, Ti, V, W and Zr) were determined with good recoveries. Th was fixed onto the resin. Based on theses results, it seems possible to analyze the forty one impurities in a U-Pu material by optimizing the operating conditions. These two protocols were used to study the presence of impurities in a Pu-based material to ensure the purity of the materials. Detection limits in the order of μg g −1 powder were obtained. • Efficient separation of cationic impurities in U-Pu matrix. • Chromatographic technique to separate cations from U, Pu and Th using UTEVA resin. • Measurement of trace and ultra-trace cations in U-Pu matrix by ICP-OES and ICP-MS.

Spectrochimica Acta Part B Atomic SpectroscopyVol. 225
Université de Montpellier (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), CEA Marcoule (FR), Institut des Sciences et technologies pour une Economie Circulaire des énergies bas carbone (FR)
Openalex Percentile: Top 19%
Radioactive element chemistry and processing
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.