PtAu‐Carbon Nanotube/Glassy Carbon Electrode Composite Based Electrochemical Sensor for High‐Precision Detection of Tetracycline
With enrichment of tetracycline (TC) in ecosystems, its accurate detection has become a major concern. Noble-metal nano-particles have attracted great interest as potential materials for sensing applications because of their remarkable electrical properties and adaptability. Herein, a novel electro-chemical detection technique based on carbon nano-tubes (CNTs) as the support material is developed to detect TC with high precision. To achieve a characteristic response to TC, a composite electrode for detection electrode is prepared by loading platinum-gold (PtAu) nano-particles on CNTs surface via electro-deposition. The oxidation peak at 0.38 V is used as the signal probe to draw a standard curve by comparing the intensities of the oxidation peaks at various TC concentrations. The PtAu-CNTs/GCE sensor exhibits remarkable sensitivity (LOD=1.05×10<sup>-8</sup> mol/L) and anti-interference properties. This study demonstrates the potential for TC detection in complex environments.
Authors
- Yukou Du (ORCID: https://orcid.org/0000-0002-9161-1821)
- Tianpeng Liu (ORCID: https://orcid.org/0000-0003-2522-656X)
- Ying Wang (ORCID: https://orcid.org/0000-0002-5437-8741)
Institutions
- Soochow University (CN)
- Jiangsu Agri-animal Husbandry Vocational College (CN)
Publication Details
- Journal
- ChemPlusChem
- Published
- 2025-01-27
- DOI
- https://doi.org/10.1002/cplu.202400525
- Citations
- 1
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.73
Funders
- National Science Foundation